5.10.2 Virtual input mapping

This Object contains the last received input data from one of the digital input panel group objects.
47 ... 40
Function data
1. Basic function field
Bit 0 to 7
Value (hex)
00
Reserved
01
Generic input
02
Standard hall call request
03
Low priority hall call request
04
High priority hall call request
05
Standard car call request
06
Low priority car call request
07
High priority car call request
08
Standard destination call
09
Low priority destination call
0A
High priority destination call
0B
Standard call to destination floor
0C
Low priority call to destination floor
2. Sub-function field
The Sub-function field is interpreted differently depending on the basic function field value.
Basic function
Sub-function
field Bit 0 to 7
field Bit 8 to
value (hex)
15 value (hex)
00
01
01
FE
FF
00
01
02
03
02 to 04
04
05
06
07 to FF
00
05 to 0D
01 to FE
FF
00
01
02
03
04
05
06
07
08
0E
09
0A
0B
0C
0D
0E
0F
10
11
39 ... 32
31 ... 24
23 ... 16
Door
Floor
Description
Description
Reserved
Generic input 1
Generic input 254
Reserved
Reserved
Hall call up
Hall call down
Hall call
Hall call extra up
Hall call extra down
Hall call extra
Reserved
Reserved
Floor number 1 to 254
Reserved
Reserved
Request fan 1
Request fan 2
Request load time 1
Request load time 2
Key lock 1
Key lock 2
Key lock 3
Key lock 4
Request door open
Request door close
Fire recall (key switch hall panel)
Fire service (key switch car panel)
Hall call disable
Attendant service
VIP service
Out of order
Bed passenger service
®
5.10 Application Profile CiA
15 ... 8
Lift
Sub-function
Bit 0 to 7
Description
Value (hex)
0D
High priority call to destination floor
0E
Special function
0F
Access code upload request
10
Speech connection request
11
Area monitoring connection request
12
Fire detector
13 to 15
Reserved
Status of safety-related circuitries
16
(This is not safety-related information.)
17 to 1F
Reserved
20
Guest call
21 to 7F
Reserved
80 to FF
Manufacturer-specific
Basic function
Sub-function
field Bit 0 to 7
field Bit 8 to
value (hex)
15 value (hex)
12
13
14
15
16
17
18
19
0E
1A
1B
1C
1D
1E
1F
20
21
22 to FF
0F to 11
00 to FF
00
12
01 to FE
FF
13 to 15
00 to FF
00
01 to 03
04
16
05
06
07 to FF
17 to 1F
00 to FF
00
20
01 to FE
FF
21 to 7F
00 to FF
80 to FF
00 to FF
5 Introduction of Functions
417 V2.1 for Lift Control Systems
7 ... 0
Basic function
Description
Special service
Service run
Dogging service enable
Dogging service up
Dogging service down
Fire alarm (external fire alarm system)
Provide priority
Lift attendant start button
Lift attendant drive through button
Security run
Second call panel
Door enable
Call cancel button fire operation
Fire alarm reset
Body detector (e.g. person in car)
Earthquake detector
Reserved
Reserved
Reserved
Fire detector 1 to 254
Reserved
Reserved
Reserved
Safety-related circuitry 1 to 3
Hall/swing door
Car door
Door lock
Reserved
Reserved
Reserved
Guest call 1 to 254
Reserved
Reserved
Manufacturer-specific
95
1
2
3
4
5
6
7
8