Removing the Hood

The hood may be easily removed to ease maintenance
procedures in the engine area of the machine.
1. Unlatch and raise the hood.
2. Remove the cotter pin securing the hood pivot to the
mounting brackets (Fig. 35).
1
Figure 35
1. Cotter pin
3. Slide the hood to the right side, lift the other side, and
pull it out of the brackets.
4. Reverse the procedure to install the hood.
General Air Cleaner
Maintenance
• Check the air cleaner body for damage which could
cause an air leak. Replace if damaged. Check the whole
intake system for leaks, damage or loose hose clamps.
• Service at the recommended service interval or earlier if
engine performance suffers due to extremely dusty,
dirty conditions. Changing the air filter before it is
necessary only increases the chance of dirt entering the
engine when the filter is removed.
• Be sure the cover is seated correctly and seals with the
air cleaner body.

Servicing the Air Cleaner

Service the air cleaner filter every 200 hours (more
frequently in extreme dusty or dirty conditions).
1. Release the latches securing the air cleaner cover to the
air cleaner body (Fig. 36).
2. Remove the cover from the air cleaner body. Before
removing the filter, use low pressure air (40 psi, clean
and dry) to help remove large accumulations of debris
packed between outside of primary filter and the
canister. Avoid using high pressure air which could
force dirt through the filter into the intake tract. This
cleaning process prevents debris from migrating into
the intake when the primary filter is removed.
2
1. Air cleaner cover
3. Remove and replace the primary filter (Fig. 37).
Cleaning of the used element is not recommended due
to the possibility of damage to the filter media. Inspect
the new filter for shipping damage, checking the sealing
end of the filter and the body. Do not use a damaged
element. Insert the new filter by applying pressure to
the outer rim of the element to seat it in the canister. Do
not apply pressure to the flexible center of the filter.
4. Clean the dirt ejection port located in the removable
cover. Remove the rubber outlet valve from the cover,
clean the cavity and replace the outlet valve.
5. Install the cover orienting the rubber outlet valve in a
downward position – between approximately 5:00 to
7:00 when viewed from the end.
1
1. Primary filter
6. Install the cover and secure the latches. Make sure that
the cover is positioned with the TOP side up.
34
1
Figure 36
2. Air cleaner latch
Figure 37

Advertisement