Electric Motor - Bosch Rexroth Hägglunds DOb Installation And Maintenance Manual

Drive unit
Table of Contents

Advertisement

66/80
Maintenance and repair
Fig. 26: Example Hoyer marking plate
Bosch Rexroth AB, Installation and maintenance manual, Hägglunds DOb, RE 15327-WA/05.2017
To get a reliable result the system must run without moving any valves and the mini-
mess hose should not touch the bottle.
Only ¾ of the bottle shall be filled because the laboratory has to shake the sample
to get a mixed fluid when they analyse it. Minimum 200 ml are needed for a good
analysis.
When the bottle is filled close the cap as soon as possible to prevent contamination
from the air to enter the bottle and give wrong result.
Air filter breather change
1. Clean the area around the air filter breather. See Fig. 2: Main components DOb
2. Remove the existing filter and dispose according to environmental regulations.
3. Mount a new filter and make sure no foreign material has entered the oil tank.

10.5 Electric motor

10.5.1 Electric motor
The main voltage and connection are marked on the electric motor marking plate,
see Fig. 26: Example Hoyer marking plate
The electric motor is used with D-connection.
Electric motor must be properly grounded.
DD00073030
Main voltage
and connection
Fig. 27: D connections
DD00062668

Advertisement