Scheduled maintenance
Planned maintenance at specific time intervals, including the following checks and
actions:
All points under frequent checks
Check all pressure levels
Check for stable temperature levels around the system
Drain water and sludge from the tank at the drain tap
Check the electric motor
Check the function of monitoring equipment/switches, etc
Cleaning.
High pressure washing
Damage on equipment
▶
Never use a high pressure washing system to clean inside the drive unit
Check the cables
Check drain line flows and drain line oil condition
Check the hoses, couplings and pump(s), with respect to cracks, leakages and
condition
Check the shaft coupling through the inspection hole.
Check the air filter in the control unit
Rotating parts!
Risk of injury.
▶
Do not touch rotating parts.
Check that the panels of the drive unit not are damaged
Table 11: Maintenace chart
Absolute max. intervals for major
inspection and replacement
After the first 100 working hours
After 3 months or 500 working hours
Once every 3 months
Once every 6 months
Once every 12 months
I = Inspection
R = Replacement
*If the contamination indicator is tripped out, the filter must be changed immediately and the oil
examined.
Hägglunds DOb, RE 15327-WA/05.2017, Installation and maintenance manual, Bosch Rexroth AB
Maintenance and repair
NOTice
CAUTIoN
Filter control
Oil filters
cabinet
-
R*
-
R*
I
-
-
-
-
R*
63/80
Air breather
Hydraulic
on tank
fluid
-
-
-
-
-
-
-
I
R
-