Check external connections

Before opening the PRISMAsync first check the external connections.
Check the following:
Procedure
1.
Power cable is connected to the PRISMAsync and the wall outlet.
2.
Power is present on the wall outlet.
3.
Network cable is connected and status LED is blinking.
4.
Crossover Ethernet cable (lower network port) is connected to the copier.
5.
Crossover Ethernet cable and normal Ethernet cable (upper network port) are not exchanged.
6.
Both data cables are connected correctly to PRISMAsync and copier.
7.
USB cable to operator panel is connected.
8.
DVI cable to operator panel is properly connected (Left DVI port).
9.
15-pin D-sub cable to operator panel is connected.
10.
9-pin D-sub cable to Operator attention light is connected
11.
Cables in the backside of the Operator panel are connected (Remove the cover on the backside of
the operator panel).
PRISMAsync V3.2