Toro Groundsmaster 5900 Installation Instructions Manual page 8

Rotary mower
Hide thumbs Also See for Groundsmaster 5900:
Table of Contents

Advertisement

8
Installing the 60-A Fuse
Parts needed for this procedure:
1
Fuse (60 A)
Procedure
Perform this procedure only if your machine is
equipped with a cab or cab power supply (i.e.,
2-Post ROPS Extension Kit or Power Harness Kit).
Figure 16
illustrates the fuses as seen from the rear of
the machine. For this procedure, replace the existing
cab power fuse (100 A) with the 60 A fuse from this kit.
Figure 16
1. 24-V-system-power fuse
(100 A)
2. Cab-power fuse (100 A)
1.
Open the cover of the cab power fuse
17).
2.
Remove the nuts from the posts of the fuse
holder
(Figure
17).
Figure 17
1. Ring terminal (yellow)
2. Nut
g285820
3. Platform-power fuse (60
A)
(Figure
g285335
3. Fuse
4. Post (fuse holder)
3.
Remove the ring terminal for the yellow wire of
the machine wire harness from the left post of
the fuse holder
4.
Remove the fuse (100 A) from the fuse holder
(Figure
17) and discard it.
5.
Install the fuse (60 A) to the fuse holder
17).
6.
Assemble the ring terminal for the yellow wire of
the machine wire harness onto the left post of
the fuse holder
7.
Assemble the 2 nuts onto the left and right posts
of the fuse-holder
8.
Torque the nuts to 14 N∙m (10 ft-lbs).
9.
Close the cover of the fuse-holder until the cover
snaps closed securely
1. Cover (fuse holder)
8
(Figure
17).
(Figure
17).
(Figure
17).
(Figure
18).
Figure 18
(Figure
g285334