Tally Setup

Tally Control Interface

Configure the pin 4 and pin 5 functions of the tally terminal using
the SETTING switch on the rear panel.
Other than pin 4 and pin 5, the remaining pin functions cannot
be changed.
1
2 3 4 5 6 7 8
.
Memo :
0 If a camera has been selected to receive tally signals, the
button corresponding to the camera appears like
Configuration method
Tally terminal pin
Function
number
1
INPUT-1
2
INPUT-2
3
INPUT-3
4
INPUT-4
OUTPUT-5
5
INPUT-5
OUTPUT-4
6
GND
7
OUTPUT-1
8
OUTPUT-2
9
OUTPUT-3
Memo :
0 The tally input or tally output supports camera number 1 to 5
of camera group 1. To use the tally input or tally output, assign
the cameras to these numbers. For details on the tally input
and tally output, refer to the "Function" column of
"Configuration method".
0 Inserting and removing of the tally terminal should be
performed while the power is turned off.
1
5
6
9
ON
.
SETTING switch
-
-
-
1
2 3 4 5 6 7 8
ON
.
1
2 3 4 5 6 7 8
ON
.
1
2 3 4 5 6 7 8
ON
.
1
2 3 4 5 6 7 8
ON
.
-
-
-
-
Connection example for TALLY OUT
Please ensure the following conditions are met.
Voltage : Maximum DC 24 V
Current : Maximum 50 mA
RC-IP100
TALLY OUT
(Maximum current
50 mA)
GND
.
Connection example for TALLY IN
Set up the contact input.
RC-IP100
+5 V
.
(Maximum voltage 24 V)
LED
TALLY IN
GND
Tally Setup