Hardware
3.7

Hardware Replacement

This section contains instructions on how to replace operator panel hardware. Only
components included in the latest bill of material and spare parts list are
allowed. See
Available Spare
3.7.1

Mode Switches

The E1000 operator panels have four mode switches (DIP switches) located on the
rear side of the operator panel.
ON DIP
1 2 3 4
Warning:
The modes below are to be used with caution.
The mode switches have the following functions:
1=ON, 0=OFF
Each letter in "MODE" has a corresponding mode switch
MODE
0000
"Run-mode" - Normal operation.
0010
System Restore, resets the file system. Restores the operator panel to factory
settings.
Warning! Information can easily accidently be lost.
0100
Image Load mode (Sysload) allows upgrading of the firmware in the operator
panel.
1000
Service Menu mode, the service menu for the system program is shown.
Allows the user to set IP configuration, erase the project etc. See section
Service Menu
1110
Self-Test.
24