Check Surroundings Around Axle and Covers for Oil
Leaks
--- every 1000 hours
Check the surroundings around the axle and covers for oil
leaks. If any oil leaks are found, check the bolts in the oil
leaking area for looseness. Retighten as needed.

Clean Axle Housing Air Breather

--- every 500 hours
Front Axle Breather (1)
Rear Axle Breather (2)
1. Clean the vicinity around the air breather before
removing the air breather.
Open the machine front cover. Front axle air breather (1)
is located at the right side.
Open the machine side cover. Rear axle air breather (2) is
located at the left side.
2. Put a cover on the air breather port to prevent foreign
matter from entering.
d
CAUTION: Be sure to wear safety glasses when
cleaning the air breather with compressed air.
3. Clean the air breather using compressed air. If
completely contaminated, wash the air breather with a
cleaning solvent and reinstall it.
4. Take care not to allow foreign matter to enter into the
axle housing when reinstalling the air breather.