DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The field current exceeds the current
-66
limit of the field transistor.
MEMORY RECALL
YES
SYMPTOM
Control will not operate
Circuits valid
•=
for
POSSIBLE CAUSE
Traction
•=Shorted field F1 to F2
Controller
•=F1 or F2 terminals shorted to battery
positive (B+)
•=F1 or F2 terminals shorted to battery
negative (B-)
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The PMT enable signal from the slave
-68
control to the master control drops
below 5V.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Slave control has shut down.
Traction
•=
Controller
•=
CORRECTIVE ACTIONS
Line contactor opens
CORRECTIVE ACTIONS
Check the slave control for stored fault
codes.
Verify the connection between P21 of the
master control and P10 of the slave control.
CAUSE OF STATUS INDICATION
This status code will be displayed when the field
transistor exceeds its specific current limit.
The line contactor will drop out and the key switch will
have to be recycled to restart the control.
TROUBLE-SHOOTING DIAGRAM
LINE
FU1
FU4
A1
+
A2
POS
A1
F1
-
S1
POWER CONNECTIONS
LEFT CONTROL
NEG
A2
F2
S2
SP
CAUSE OF STATUS INDICATION
This status code will be displayed when the voltage at
PL21 of the master control drops below 5V.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH
P1
PY11
P21
PY12
MASTER
CONTROL
Page 39
POS
A1
F1
POWER CONNECTIONS
RIGHT CONTROL
NEG
A2
F2
P1
P21
PY12
PY11
P10
SLAVE
CONTROL