GE IC3645SR3R404P2 Installation And Operation Manual page 26

Separately excited (sx) transistorized dual motor controllers
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Motor field current is high on start up in
-23
the reverse direction.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
POSSIBLE CAUSE
for
Defective control.
Traction
•= Replace controller unit.
Controller
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Motor field current is high on start up in
-24
the forward direction.
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Defective control.
Traction
•= Replace controller unit.
Controller
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when the current
draw in the motor field is too high at start up in the
reverse direction.
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE
CAUSE OF STATUS INDICATION
This status code will be displayed when the current
draw in the motor field is too high at start up in the
forward direction.
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE