DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
There is an open circuit in the line
-64
contactor coil.
MEMORY RECALL
YES
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Missing line contactor coil wire.
Traction
•= Verify line contactor coil wiring.
Controller
Defective line contactor coil.
•= Replace line contactor coil.
Defective control.
•= Replace controller unit.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
There is a short in either the steer
-65
pump or the line contactor coil.
MEMORY RECALL
YES
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Shorted steer pump contactor coil.
Traction
•= Verify steer pump contactor coil wiring.
Controller
Shorted line contactor coil.
•= Verify line contactor coil wiring.
Defective control.
•= Replace controller unit.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when P17 does not
see battery voltage while the contactor is open.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
SP
P1
P2
P18
CAUSE OF STATUS INDICATION
This status code will be displayed when either the
steer pump or the line contactor coil is shorted.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
SP
P1
P2
P18
Page 38
L
P17
L
P17
July 1999