1.5.4.9
Special Carrier Access Code
Description
If the PBX has access to multiple telephone companies, a Special Carrier Access code assigned through
system programming (→ Special Carrier Access Code [303]) is required every time a trunk call is made.
A preprogrammed Pause time (→ LCOT Pause Time [416]) will be automatically inserted between the user-
dialled Special Carrier Access code and the digits that follow. (→ 1.5.4.7 Pause Insertion)
Conditions
•
TRS/Barring
TRS/Barring checks only the dialled telephone number excluding the Special Carrier Access code. (→
1.8.1 Toll Restriction (TRS)/Call Barring (Barring))
•
If this PBX is installed behind an existing host PBX:
A Special Carrier Access code and a Host PBX Access code should be assigned separately: these
codes cannot be assigned together as one code. (→ 1.5.4.8 Host PBX Access Code (Access Code to
the Telephone Company from a Host PBX))
1.5 Making Call Features
Feature Guide
85