Service Programming; Inspira And Advanta - G 118X/G 2170/G 218X - Miele G 1 Series Technical Information

Hide thumbs Also See for G 1 Series:
Table of Contents

Advertisement

Technical Information
4.2

Service Programming

4.2.1

Inspira and Advanta - G 118x/G 2170/G 218x

Initial requirements:
1. Open the door.
2. Switch off the appliance.
Accessing:
1. Press and hold the Program button.
2. Switch on the appliance.
3. Release the Program button.
4. Immediately press the Program button 5 times; on the 5th time, hold until
the "Rinse & Hold" LED flashes (5 flashes per second).
5. Release the Program button.
6. If the "Rinse & Hold" LED does not light up, repeat the procedure.
Options:
Function
Reset
Water hardness setting
Dispensed rinse aid
quantity setting
Programming
Press the Program button
1x. To reset all parameters
to standard settings, press
and hold the Program
button until the
"Intake/Drain" LED lights
up. Then briefly press the
Program button.
Briefly press Program 2x.
To set the desired water
hardness, press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then select the
desired value by briefly
pressing the Program
button as appropriate.
Briefly press Program 3x.
To set the desired
quantity, press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then select the
desired value by briefly
pressing the Program
button as appropriate.
166
G 1xxx/G 2xxx
Display
The "Intake/Drain" LED flashes 1x
rapidly. "SaniWash" LED is off:
values do not correspond to
standard settings; "SaniWash" LED
flashes: values correspond to
standard settings.
The "Intake/Drain" LED flashes 2x
rapidly at intervals. The set value is
indicated by the "SaniWash" LED
flash pattern. If the "SaniWash" LED
flashes 4x rapidly at intervals, this
corresponds to the standard setting
of 12 - 15°d (12.8 - 16.1 gpg); see
2
Table 080-6.
The "Intake/Drain" LED flashes 3x
rapidly at intervals. The set value is
indicated by the "SaniWash" LED
flash pattern. If this LED flashes 3x
rapidly at intervals, this corresponds
to the standard setting of 0.1 fl.oz.
(3mL). Range: 0 - 0.2 fl.oz. (0 - 6
mL); see Table 080-7.

Advertisement

Table of Contents
loading

Table of Contents