Various new functions for flexible use.
Additional CF card unit on the GOT main unit.
Increased functionality of the expansion drive.
CF card unit
●
The standard CF card interface unit (A drive) and optional CF card interface unit (B drive) can be
used for separate purposes. By addings a new optional interface operation safety is ensured by
avoiding removal of necessary data which should always be stored in the GOT.
Product name
CF card interface unit
Expanded connectable FA equipment.
Now it's easier to connect than ever.
Enhanced connectivity
Other brand PLCs
【GT15/GT11】
●
Expanded manufacturers and models of PLCs.
・Fuji Electric FA Components & Systems:
・Hitachi:
S10V series (LQP510/520), S10mini series (LQP800/000/010/011/120)
Temperature controllers
●
Expanded manufacturers and models of temperature controllers
・Shinko Technos digital indicating controllers:
ACS-13A series, JC series, JCM-33A series, JIR-301-M series,
FCD-100 series, FCR-100 series, FCR-23A series, FIR series, PC-900 series, DCL-33A series
・Yokogawa Electric temperature controllers:
GREEN series (UT/UP/UM/US), UT100 series (UT/UP), UT2000 series
Other
【GT15】
●
By setting the network ID, stations in other networks (Ethernet,
MELSECNET/H) can be monitored.
*For more details on of connectable models and connection configurations, refer to the GOT1000 Series
Connection Manual.
Enhanced functionality of SoftGOT1000.
More flexibility in system architecture.
Multiple Instances
●
Multiple instances of GT SoftGOT1000 can run on a single personal computer,
allowing monitoring of multiple devices from various connection configurations.
Internal device interface functions
●
By using internal device interface functions, user-created applications can
read/write data from/to the GOT internal devices. In addition, it is possible
to link data to user applications such as a data logger in order to develop
advanced systems that can run in cooperation with applications.
<Development environment of user applications>
Microsoft(R) Visual C++(Version 6.0), Microsoft(R) Visual Basic (Version 6.0)
New functions
15
GOT1000
GRAPHIC OPERATION TERMINAL
Model name
GT15-CFCD
GOT1000
GRAPHIC OPERATION TERMINAL
MICREX-F series (F55/70/120S/140S/15□S)
【GT15/GT11】
GOT1000
GRAPHIC OPERATION TERMINAL
GT
CF card interface unit
(GT15-CFCD)
〈Run multiple programs〉
Monitoring
Line1
Monitoring
Line2
Q25HCPU
QX10
QX41
Q61P-A1
POWER
MODE
RUN
ERR
BAT
USER
BOOT
0
1
2
3
4
PULL
5
6
7
8
USB
9
A
B
C
D
PULL
E
F
Line1
− 1 −
Save screen data and logging data
that should remain in the GOT
Save CSV and other data
that can be removed
during operation
GT SoftGOT1000 personal computer
Monitor for
Monitor for
Line1
Line3
Monitor for
Monitor for
Line2
Line4
Ethernet connection
QX41
QJ71BR11
QJ71BR11
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
RUN
MNG
RUN
MNG
Q61P-A1
POWER
RUN
MNG
RUN
MNG
Q61P-A1
POWER
RUN
MNG
RUN
MNG
Q61P-A1
T.PASS
SD
RD
D.LINK
T.PASS
SD
D.LINK
RD
MODE
T.PASS
SD
RD
D.LINK
T.PASS
SD
D.LINK
RD
MODE
T.PASS
SD
RD
D.LINK
T.PASS
SD
D.LINK
RD
ERR
ERR
ERR
ERR
RUN
ERR
ERR
ERR
ERR
RUN
ERR
ERR
ERR
ERR
ERR
ERR
USER
BAT
USER
BAT
BOOT
BOOT
0
0
1
1
2
2
3
3
4
4
PULL
5
PULL
5
PULL
6
6
7
7
8
8
USB
9
USB
9
A
A
B
B
C
C
D
D
PULL
E
PULL
E
F
F
Line2
Line3
【Benefit】
Multiple devices can be monitored from a
single personal computer.
Standard
A drive
Optional
B drive
Monitoring
Line3
Monitoring
Line4
Q25HCPU
QX10
QX41
QX41
QJ71BR11
QJ71BR11
POWER
RUN
MNG
RUN
MNG
MODE
T.PASS
SD
D.LINK
RD
T.PASS
SD
RD
D.LINK
RUN
ERR
ERR
ERR
ERR
ERR
BAT
USER
BOOT
0
1
2
3
4
5
6
7
8
USB
9
A
B
C
D
PULL
E
F
Line4