<Calculation Example>
● Calculation Example 1: For use in Europe
(OFF response time: 15ms or less, minimum sensing object diameter: 27mm)
First, calculate with K = 2,000.
S = K × T + C
= K × (T
m
= 2,000 × (T
= 2,000 × T
= 2,000 × T
If the result is:
1) In case S < 100 (mm)
Safety distance S is taken as 100 (mm)
2) In case 100 ≤ S ≤ 500 (mm)
Safety distance S is taken as 2,000 × T
3) In case S > 500 (mm)
S = K' × (T
= 1,600 × (T
= 1,600 × T
= 1,600 × T
then, calculate again.
If the result is:
4) In case S ≤ 500 (mm)
Safety distance S is taken as 500 (mm)
5) In case S > 500 (mm)
Safety distance S is taken as 1,600 × T
In case this device is installed in a system with a maximum halting time of 0.1 (sec.)
S = 2,000 × T
= 2,000 × 0.1 + 134
= 334
Since this value matches with Case 2) above, S is 334 (mm).
In case this device is installed in a system with a maximum halting time of 0.4 (sec.)
S = 2,000 × T
= 2,000 × 0.4 + 134
= 934
Since this value matches with Case 3) above,
S = 1,600 × T
= 1,600 × 0.4 + 128
= 768
Since this value matches with Case 5) above, S is 768 (mm).
16
Ramco Innovations | www.ramcoi.com | 800-328-6236 | nsales@ramcoi.com
+ T
) + 8 × (d - 14)
SF2B
+ 0.015) + 8 × (27 - 14)
m
+ 2,000 × 0.015 + 104
m
+ 134
m
+ T
) + 8 × (d - 14)
m
SF2B
+ 0.015) + 8 × (27 - 14)
m
+ 1,600 × 0.015 + 104
m
+ 128
m
+ 134
m
+ 134
m
+ 128
m
+ 134 (mm)
m
+ 128 (mm)
m
© Panasonic Industrial Devices SUNX Co., Ltd. 2016