Main circuit terminal specifications
Single-phase 200V class
FR-E720S-008 to 030
Screw size (M3.5)
N/-
R/L1 S/L2
Screw size
(M3.5)
Power supply
Single-phase 100V class
FR-E710W-008 to 030
Screw size (M3.5)
N/-
R/L1 S/L2
Screw size
Power supply
NOTE
Make sure the power cables are connected to the R/L1, S/L2, T/L3. Never connect the power cable to the U, V, W of the
inverter. (Phase need not be matched.) Doing so will damage the inverter.
Connect the motor to U, V, W. Turning ON the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.
8
Jumper
P/+
PR
IM
Motor
Jumper
P/+
PR
IM
(M3.5)
Motor
FR-E720S-050 to 110
Jumper
N/- P/+
Screw size (M4)
R/L1 S/L2
PR
Power supply
FR-E710W-050
Jumper
N/- P/+
Screw size (M4)
R/L1 S/L2
PR
Power supply
IM
Screw size
(M4)
Motor
IM
Screw size
(M4)
Motor