Bay control REC670
Version 2.2
Table 10. Basic IED functions, continued
IEC 61850 or function
Description
name
ALTMS
Time master supervision
ALTIM
Time management
CAMCONFIG
Central account management configuration
CAMSTATUS
Central account management status
TOOLINF
Tools information
COMSTATUS
Protocol diagnostic
Table 11. Local HMI functions
IEC 61850 or function
ANSI
name
LHMICTRL
LANGUAGE
SCREEN
FNKEYTY1–FNKEYTY5
FNKEYMD1–FNKEYMD5
LEDGEN
OPENCLOSE_LED
GRP1_LED1–
GRP1_LED15
GRP2_LED1–
GRP2_LED15
GRP3_LED1–
GRP3_LED15
4. Control
Synchrocheck, energizing check, and synchronizing
SESRSYN
The Synchronizing function allows closing of
asynchronous networks at the correct moment including
the breaker closing time, which improves the network
stability.
Synchrocheck, energizing check, and synchronizing
(SESRSYN) function checks that the voltages on both
sides of the circuit breaker are in synchronism, or with
at least one side dead to ensure that closing can be
done safely.
SESRSYN function includes a built-in voltage selection
scheme for double bus and 1½ breaker or ring busbar
arrangements.
Manual closing as well as automatic reclosing can be
checked by the function and can have different settings.
28
Description
Local HMI signals
Local human machine language
Local HMI Local human machine screen behavior
Parameter setting function for HMI in PCM600
General LED indication part for LHMI
LHMI LEDs for open and close keys
Basic part for CP HW LED indication module
M12480-3 v16
© Copyright 2017 Hitachi Power Grids. All rights reserved
For systems, which can run asynchronously, a
synchronizing feature is also provided. The main
purpose of the synchronizing feature is to provide
controlled closing of circuit breakers when two
asynchronous systems are in phase and can be
connected. The synchronizing feature evaluates voltage
difference, phase angle difference, slip frequency and
frequency rate of change before issuing a controlled
closing of the circuit breaker. Breaker closing time is a
setting.
Autorecloser SMBRREC
The auto recloser (SMBRREC) function provides:
• high-speed and/or delayed auto reclosing
• single and/or three phase auto reclosing
• support for single or multi-breaker applications.
The auto recloser can be used for delayed busbar
restoration.
Up to five reclosing shots can be performed. The first
shot can be single-, two-, and /or three-phase
1MRK 511 404-BEN N
M12390-3 v17
Hitachi Power Grids