DC link components
7.2 Braking Module Booksize
7.2.7
Installation
①
State when supplied with spacer
②
Spacer removed - mounting depth for S120 Combi
Figure 7-10
Methods of installing Braking Modules with/without spacer elements
7.2.8
Technical data
Table 7- 11
Technical data
6SL3100-1AE31-0AB.
DC link voltage
DC link capacitance
ON threshold
174
V
DC
µF
V
510 ... 720
110
770
Manual, 11/2017, 6SL3097-4AV00-0BP7
SINAMICS S120 Combi