3 axes Power Modules
Output current
Rated current (I
)
n
Base-load current (I
)
H
Intermittent duty current for S6 duty I
Peak current (I
)
max
Rated power
at 540 V DC link voltage
at 600 V DC link voltage
Pulse frequency feedrate 2
Output voltage
Output for expansion axis
DC link voltage
DC link output current (I
n
Max. electronics output current for expansion axis
General data
Electronics current drawn at 24 V DC
without external fan unit
with external fan unit
Total power loss
(including losses from the electronics, see Power
loss tables (Page 300))
internal
external
The external 6SL3161-0EP00-0AA0 fan module is
taken into account for the specified losses – also
see Power loss calculation for partial load opera-
tion (Page 302).
Max. ambient temperature
Without derating
With derating
DC link voltage
DC link capacitance
Overvoltage tripping
Undervoltage tripping
Circuit breaker/fuse
(IEC 60947 and UL)
Resulting rated short-circuit current SCCR at
480 V AC
Cooling method
Cooling air requirement
Weight
The specified power ratings apply to the line voltage range from 380 V to 480 V
1)
SINAMICS S120 Combi
Manual, 11/2017, 6SL3097-4AV00-0BP7
(40%)
S6
)
6SL3111-
3VE21-6FA1
A
5
ACrms
A
4.3
ACrms
A
6.5
ACrms
A
10
ACrms
kW
2.4
kW
2.7
kHz
4
V
0 ... 0.7 x DC link voltage
ACrms
V
460 ... 720
DC
A
40
DC
A
20
24Vmax
A
1.5
A
2.3
W
425
W
81
W
344
°C
45
°C
55
V
460 ... 720
DC
μF
1645
V
820 ± 2 %
DC
V
380 ± 2 %
DC
See Chapter Line-side overcurrent protective devices
(Page 34)
kA
65
External air cooling
m
/h
160
3
kg
18.35
S120 Combi Power Modules
4.9 Technical data
3VE21-6EA1
3VE22-0HA1
9
9
7.7
7.7
12
12
18
18
4.3
4.3
4.8
4.8
4
4
1.5
1.5
2.3
2.3
537
634
91
102
446
532
45
45
55
55
1880
2115
65
65
160
160
18.4
18.5