E007-0102: Pressure Belt Home Position Detection Error; E007-9902: Abnormality Of The Pressure Belt Displacement - Canon imagePRESS C800 Series Technical Workbook

Hide thumbs Also See for imagePRESS C800 Series:
Table of Contents

Advertisement

T E C H N I C A L
W O R K B O O K
2) Inspect the Connectors from the Fixing Belt Displacement Control Motor Unit to the Fixing Feeding
Driver PCB. Look for loose Connectors and Bent Pins. Fasten the Connectors if a disconnection is found
or connect the Connectors again if a Connector is not plugged.
3) Inspect the Fixing Belt HP Sensor Flag and replace it if any abnormality of appearance or a breakage is
found.
4) If any of the procedures up to 3) does not work, replace the Fixing Belt HP Sensor (PS69).
5) If the step 4) does not work, replace the Fixing Belt Displacement Control Motor (M46).
6) If the step 5) does not work, replace the FIXING DRIVER PCB.
7) If the step 6) does not work, replace the DC Controller PCB.

E007-0102: Pressure Belt Home Position Detection Error

An E007-0102 Error is usually due to an abnormality in the Position Sensor in conjunction with motor motion in
the Pressure Belt Displacement Control. Inspect to see if faulty mounting or abnormal connection of the Pressure
Belt Unit by using the subsequent procedure. Do not replace the Pressure Belt Unit yet as this error is not
normally due to an abnormality of the unit.
1) Inspect the mounting of the Pressure Belt Displacement Control Motor Unit and re-mount it properly
if any abnormality is found.
2) Inspect the connection from the Pressure Belt Displacement Control Motor Unit to the Fixing Feeding
Driver PCB. Look for loose connectors and bent pins. Fasten the connectors if a disconnection is found
or connect the connectors again if a connector is not plugged.
3) Inspect the Pressure Belt HP Sensor Flag and replace it if an abnormality of appearance or a breakage is
found.
4) If any of the procedures up to 3) does not work, replace the Pressure Belt HP Sensor (PS78).
5) If the step 4) does not work, replace the Pressure Belt Displacement Control Motor (M49).
6) If the step 5) does not work, replace the Fixing Driver PCB.
7) If the step 6) does not work, replace the DC Controller PCB.

E007-9902: Abnormality of the Pressure Belt Displacement

An E007-9902 Error usually occurs due to a failure or connection abnormality of the Pressure Belt Position
Sensor 1 and 2.
1) Check the connection of electrical parts and the detection situation of the Pressure Belt Position Sensor
1 and 2. If the value of Service Mode > DISPLAY > ANALOG > FX-L-POS is "0, 1, 1" or "1, 1, 1", the
Pressure Belt Position Sensor 1 or 2 has connection abnormality or a failure.
2) Reconnect the connectors of the Pressure Belt Position Sensor 1 and 2 (PS76 and 77)
3) If reconnecting connectors does not work, check the cable and replace it if a disconnection is found.
4) If none of the above remedies works, replace the Pressure Stay Assembly.