If the Grease on the moving Gears [1] of the Fixing Belt Unit is depleted, apply the Grease (SE1107) onto
entire circumference of the Gear [A] surfaces as needed.
[1]
[A]
[A]
After replacement of the Fixing Belt Unit, be sure to execute Counter Clear for the unit. Navigate to Service
Mode: FUNCTION> DRBL-1 >FX-BLY-U " to execute the Counter Clear. If a Count Clear is not executed,
the data history before replacement of the unit is resumed. This can eventually result in E007-0001, 0011 and
0021 Errors.
Use Care When Mounting the Pressure Belt Unit
If the Pressure Belt Unit is not mounted properly, the issues which could develop are Faulty Images and E004-
0101 Errors which result due to the breakage of the Halogen Heater.
1) Before mounting the Pressure Belt Unit, check if the Bearings at both ends of the Pressure Roller do not run
on the Support Plate. If they do, correct their positions.