Advertisement

-M
Air
neo

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NeoAir V2-M and is the answer not in the manual?

Questions and answers

Summary of Contents for Heatmiser NeoAir V2-M

  • Page 2: Product Image

    Model: Series...
  • Page 3: Table Of Contents

    Table Of Contents Hot Water Boost Product Image Locking/Unlocking the neoAir V2-M Table of Contents Installation Procedure Frost Protection Installing the batteries Power ON/OFF Mode Select Holiday Programming Receiver Type Optional Features Explained 34-35 Pairing with the UH8-RF 10-11 Adjusting the Optional Settings...
  • Page 4: Installation Procedure

    Installation Procedure Mount the thermostat at eye level. Read the instructions fully so you get the best from our product. Don’t Do not install near to a direct heat source as this will a ect functionality. Do not push hard on the LCD screen as this may cause irreparable damage. This wireless thermostat is designed to be surface mounted.
  • Page 6: Installing The Batteries

    Installing the Batteries 4 x AAA batteries have been supplied with the neoAir V2-M. To access the battery holder, push and release the compartment door located on the bottom face of the thermostat. The thermostat will inform you when the batteries need to be replaced by displaying the battery icon on screen.
  • Page 7 Insert the batteries in the empty battery holder, ensuring that each battery is orientated for the correct polarity + / -. Push the battery holder back inside the thermostat until it is secured in its closed position.
  • Page 8: Mode Select

    Mode Select Before pairing the neoAir V2-M to your receiver, set the correct mode for your installation. Three di erent modes are available; Mode 2 = Timer Mode 3 = Thermostat & HW Timer Mode 1 = Thermostat Check the compatibility table below for the receiver you are using.
  • Page 9: Receiver Type

    Receiver Type The neoAir V2-M will send a wireless signal to a receiver to switch on the heating or hot water*. Select the receiver type you are using from the list shown here on pages 8 - 9 and follow the pairing instructions on the relevant page.
  • Page 10 RF-Switch: Page 12 RF-Switch 16 Amp: Page 13 neoHub Mini OT: Page 14-15 neoHub Mini HW: Page 16-17 Series...
  • Page 11: Pairing With The Uh8-Rf

    Pairing with the UH8-RF Wiring Centre Channel Number Remove the cover from the UH8-RF. The current channel number is set inside on the two dials, these dials are at the top of the circuit board and look like this (TENS) (UNITS) (You need to set a unique channel number for each UH8-RF) Example showing...
  • Page 12 • The two large numbers in the centre will ash, use the up/down arrow keys to set this to the channel number of your UH8-RF................• Press once to con rm........................• The two small numbers at the top will ash, this represents the zone number the neoAir will be switching, use the up/down arrow keys to adjust.......
  • Page 13: Pairing With The Rf-Switch

    Pairing with the RF-Switch To control heating only, con gure the neoAir in mode 1. To control heating & hot water, con gure the neoAir in mode 3. (See page 7) On the neoAir: • Use the Left arrow key to highlight on the menu ..............
  • Page 14: Pairing With The Rf-Switch 16 Amp

    Pairing with the RF-Switch 16 Amp Con gure the neoAir in mode 1, as explained on page 7, then follow the steps below. On the neoAir: • Use the Left arrow key to highlight on the menu ..............• Press and hold for 3 seconds ......................
  • Page 15: Pairing With The Neohub Mini Ot

    Pairing with the neoHub Mini OT Con gure the neoAir in mode 1, as explained on page 7. To control a single heating zone, pair the neoAir to the CH1 output. To control a second heating zone, pair the next neoAir to the CH2 output. As explained below.
  • Page 16 On the neoAir V2-M: • Use the Left arrow key to highlight on the menu............• Press and hold for 3 seconds..................... • SETUP is now highlighted, press once to access the setup menu........• The display will show the number 01 in the top right corner.
  • Page 17: Pairing With The Neohub Mini Hw

    Pairing with the neoHub Mini HW To control a single heating zone & hot water, con gure the neoAir in mode 3 (see page 7), then pair the neoAir to the CH1 output. The neoAir will automatically pair to the HW output at the same time. To control a second heating zone, con gure the neoAir in mode 1 (see page 7), then pair the neoAir to the CH2 output.
  • Page 18 On the neoAir V2-M: • Use the Left arrow key to highlight on the menu............• Press and hold for 3 seconds..................... • SETUP is now highlighted, press once to access the setup menu........• The display will show the number 01 in the top right corner.
  • Page 19: Pairing With The Neohub

    • Once you’ve paired the hub to your account, the next step is to add the neoAir V2-M. The app will prompt you to ‘Add Zone’. Follow the instructions in the app by entering a title for the zone &...
  • Page 20 To pair any additional Neo’s, select the + icon in the app, then ‘Add Thermostat’. NeoAir and MESH The neoAir V2-M is not capable of relaying signals from one thermostat to another (MESH). To create an extension of the wireless mesh network you will need to add a neoPlug* or Heatmiser Boost to the system.
  • Page 21: Mode 1 & 3 - Thermostat

    & Modes 1 & 3 – Thermostat/ Thermostat with Hot Water...
  • Page 22 Series...
  • Page 23: Lcd Display

    LCD Display Mesh Symbol - Displayed when connected to the neoHub, neoHub Mini HW/OT Day Indicator - Displays the day of the week. Frost Symbol - Displayed when frost protection/standby mode is active. Flame Symbol - Displayed when the thermostat is calling for heat. Holiday –...
  • Page 24: Setting The Clock

    Setting the Cloc To set the clock, follow these steps. • • Use the Left / Right arrow keys to highlight on the menu......• Press and hold to turn o the display ................ • Use the right arrow key to select CLOCK ............... •...
  • Page 25: Comfort Levels Explained

    Comfort Levels Explained The neoAir V2-M o ers the following program mode options; Weekday/Weekend (Mon-Fri/Sat-Sun) • • 7 Day (Each day programmed di erently) • 24 Hour (All days the same) • Non-Programmable (Simple up/down temperature control, no timing) Follow the optional settings instructions to rst set your prefered program mode.
  • Page 26 • Use the Up / Down keys to set the hours .............. • Press to con rm ........................ • Use the Up / Down keys to set the minutes ............• Press to con rm ........................ • Use the Up / Down keys to set the temperature ..........•...
  • Page 27: Temperature Control

    Temperature Control • The Up / Down keys allow you to adjust the set temperature ........• When you press either key, you will see the word SET and the desired temperature value. Use the Up / Down keys to adjust the SET value ..... •...
  • Page 28 Temperature Hold (Mode 01 Heating only) The temperature hold function allows you to manually override the current operating program and set a di erent temperature for a desired period. • Use the Left / Right keys to scroll to HOLD ............•...
  • Page 29: Temperature Hold

    Temperature Hold (Mode 03 Heating and Hot Water) The temperature hold function allows you to manually override the current operating program and set a di erent temperature for a desired period. • Use the Left / Right keys to scroll to HOLD ............•...
  • Page 30: Hot Water Boost

    Hot Water Boost (Mode 03 Heating and Hot Water) To boost the hot water output on, follow these steps. • Use the Left / Right keys to scroll to HOLD .............. • Press to con rm ......................... • T he word “Heating” is highlighted, use the Left / Right keys to select TIMER then press to con rm ................
  • Page 31: Locking/Unlocking The Neoair

    Locking the neoAir V2-M The neoAir has a touch key lock facility. To activate the lock follow these steps. • Use the Left / Right keys to scroll to HOLD & press for 10 seconds. • The display will show 00:00 and you will need to enter a four digit pin number.
  • Page 32: Frost Protection

    Frost Protection Mode Enabled In this mode, the neoAir V2-M will only turn ON the heating should the room temperature drop below your frost temperature setting, which as default is 12˚C. •...
  • Page 33: Power On/Off

    Power On/O To turn o the neoAir V2-M’s display; Use the Left arrow key to highlight on the menu..............• • Press and hold for 3 seconds ......................The display will show , temperature display & heating output is now turned OFF.
  • Page 34: Holiday Programming

    Holiday In thermostat mode, the holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 34). The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return. In time clock mode, the holiday function maintains the timed output as OFF.
  • Page 35: Optional Features Explained

    THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED NOT BE ADJUSTED Feature 01 – Pairing To Hub: This function is used to pair the neoAir V2-M to the following; neoHub / neoHub Mini HW / neoHub Mini OT Feature 02 - Switching Di erential: This function allows you to increase the switching di erential of the thermostat.
  • Page 36 If the receiver fails to receive a signal from the neoAir V2-M within a 40 minute period, it will activate the output for 12 minutes every hour. The receiver will continue to do this until it receives a signal from the neoAir V2-M. Series...
  • Page 37: Adjusting The Optional Settings

    Adjusting the Optional Settings • Use the Left arrow key to highlight on the menu ..............• Press and hold for 3 seconds ......................• SETUP is now highlighted, press once to enter the setup menu........The small number at the top right is the feature number. The large number in the centre is the setting within the feature, as shown below;...
  • Page 38: Optional Settings Feature Table

    Optional Settings - Feature Table FEATURE DESCRIPTION SETTING Failsafe 00 = Disabled 01 = Enabled (Default) Pairing to UH8-RF 00 – 99 = Receiver address/zone no. & type Pairing to RF-Switch Commences countdown from 99 – 00 seconds. Pairing to Hub Used to add zone to the neoHub/neoHub Mini Menu Entry Point...
  • Page 39: Re-Calibrating The Thermostat

    Re-calibrating the Thermostat To re-calibrate the temperature reading, follow these steps. • Use the Left arrow key to highlight on the menu ..........• Press and hold for 3 seconds to turn o the display ........... • Press and hold and Down arrow keys together for 10 seconds....
  • Page 40: Factory Reset

    The neoAir V2-M will revert to the main display for the selected mode. Note: Factory reset will erase all parameters that were entered during pairing and programming. You will need to pair the neoAir V2-M to your receiver after factory reset is completed. Series...
  • Page 41: Remote Sensor Probe Wiring

    Remote Sensor Probe Wiring...
  • Page 42: Mode 2 - Time Clock

    Mode 2 - Time Clock Model: Manual REF Series...
  • Page 43: Lcd Display

    LCD Display Comms Symbol - Displayed when connected to the neoHub. Day Indicator - Displays the day of the week. Holiday – Displayed when the time clock is in holiday mode. Set - Displayed when changes are being made to the current set point. Program Indicator - Displayed during programming to show which level is being altered.
  • Page 44: Setting The Switching Times

    Setting the Switching Times To program the switching times, follow these steps. • Use the Left / Right keys to scroll to EDIT and press ........• Use the Left / Right keys to select day/period of the week ......•...
  • Page 45: Timer Override

    Timer Override To override the timed output on, follow these steps. • Use the Up / Down keys to set the override duration e.g. 02:00 hours ..• Press to con rm settings and return to main display ........Hold Left and the remaining time will now be displayed. HOLD LEFT Indicator Hold Time Remaining •...
  • Page 46: Optional Features Explained

    Optional Features Explained Feature 01 – Pairing To neoHub: This function is used to connect the timeclock to the neoHub. Feature 02 – Program Mode: The time clock o ers three programming modes. Weekday/ Weekend - 4 Switching times for Monday - Friday. 4 di erent switching times for Saturday - Sunday.
  • Page 47: Optional Settings Feature Table

    Optional Settings - Feature Table FEATURE DESCRIPTION SETTING 00 = Disabled Failsafe 01 = Enabled (Default) 00 – 99 = Receiver address, zone no. & type Pairing to UH8-RF Commences countdown from 99 – 00 seconds. Pairing to RF-Switch Used to add zone to the neoHub Pairing to Hub Menu Entry Point...
  • Page 48 Want More Information? Call our support team on: +44 (0)1254 669090 Or view technical speci cations directly on our website: www.heatmiser.com Heatmiser UK Ltd Units 1-5 Hurstwood Court, Mercer Way Shadsworth Business Park, Blackburn, Lancashire, BB1 2QU, United Kingdom. Twitter: @heatmiseruk Facebook: facebook.com/thermostats...

Table of Contents

Save PDF