Summary of Contents for Heatmiser neostat

  • Page 2: Product Image

    Model: Available in : Sapphire Black and Glacier White Series...
  • Page 3: Table Of Contents

    Table of Contents Product Image Locking/Unlocking the neoStat Table of Contents Frost Protection What is a Programmable Power ON/OFF Room Thermostat? Holiday Programming Installation Procedure 23-26 Optional Features Mode Select Re-calibrating the Thermostat Pairing the neoHub Error Codes Pairing the neoStat...
  • Page 4: What Is A Programmable

    What is a Programmable Room Thermostat? Section Header A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set “On” and “Off” periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
  • Page 5 Section Header The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature –...
  • Page 6: Installation Procedure

    Do not push hard on the LCD screen as this may cause irreparable damage. This neoStat is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation.
  • Page 7 Section Header...
  • Page 8: Mode Select

    Mode Select Section Header This neoStat can either be used as a thermostat or a time clock. Thermostat mode is the default setting. To change between thermostat or time clock modes, follow these steps. • Use the Left / Right keys to scroll to SETUP ..............
  • Page 9: Pairing The Neohub

    • Select Add Zone, enter a zone title and press Add Zone again. • You now have two minutes to join the neoStat to the neoHub. • On the neoStat, use the Left / Right keys to select SETUP and press Tick ... • Feature 01 is displayed on screen.
  • Page 10: What Is A Mesh Network

    • Press the Tick key to pair the neoStat to the neoHub ........Section Header • The MESH symbol appears flashing on the display. • When the neoStat successfully connects to the neoHub the MESH symbol will be permanently displayed.
  • Page 11: Mode 1 - Thermostat

    Mode 1 - Thermostat Section Header...
  • Page 12 Section Header Series...
  • Page 13: Lcd Display

    LCD Display Section Header Day Indicator - Displays the day of the week. Mesh Symbol - Displayed when connected to the neoHub. Floor Limit Symbol - Displayed when the floor probe has reached the temperature limit set on feature 07. Frost Symbol - Displayed when frost protection mode is active.
  • Page 14: Temperature Display

    Room Temperature Floor Temperature When the neoStat is set to use both the air & the floor sensor, the room temperature will be displayed by default. To view the current floor temperature, press and hold the Left and Right arrow keys for 5 seconds, the floor temperature will then be displayed ........
  • Page 15: Setting The Clock

    Setting the Clock Section Header To set the clock, follow these steps. • Use the Left / Right keys to scroll to CLOCK ............• Press Tick to confirm selection ................... • Use the Up / Down keys to set the hours (24 hour format) ......•...
  • Page 16: Setting The Comfort Levels

    Comfort Levels Explained Section Header The neoStat offers three program mode options; Weekday/Weekend programming, 7 Day programming and 24 Hour programming. There is also the option to use the thermostat as a Non-Programmable thermostat. When thermostats are connected to the mesh network, the program mode for the system is configured by using the neoApp.
  • Page 17 Section Header • Use the Up / Down keys to set the hours .............. • Press Tick to confirm ......................• Use the Up / Down keys to set the minutes ............• Press Tick to confirm ......................• Use the Up / Down keys to set the temperature ..........•...
  • Page 18: Setting The Temperature

    Temperature Control Section Header The Up / Down keys allow you to adjust the set temperature ......When you press either key, you will see the word SET and the desired temperature value. Use the Up / Down keys to adjust the SET value ....Press Tick to confirm settings and return to the main display ........
  • Page 19: Temperature Hold

    Temperature Hold Section Header The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period. • Use the Left / Right keys to scroll to HOLD ............• Press Tick to confirm selection ..................•...
  • Page 20: Locking/Unlocking The Neostat

    The frost icon will toggle ON/OFF each time Tick is pressed ..........In this mode, the neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature (see page 23).
  • Page 21: Frost Protection

    The frost icon will toggle ON/OFF each time Tick is pressed ..........In this mode, the neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature (see page 23).
  • Page 22: Power On/Off

    When the flame icon is absent, there is no requirement for heating to achieve the set temperature but the neoStat remains active. To turn the neoStat off completely, scroll to the Power Icon and hold the Tick key for approximately 4 seconds until the display goes blank ....
  • Page 23: Holiday Programming

    Holiday Section Header In thermostat mode, the holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 23). In time clock mode, the holiday function maintains the timed output as OFF. The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return.
  • Page 24: Optional Features

    Feature 06 – Sensor Selection: On this neoStat, you can select which sensor should be used. You can select between air temperature only, floor temperature, or both. When you enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to prevent the floor from overheating.
  • Page 25 Feature 07 – Floor Temp Limit: This function is available when mode 07 is set to 03 or 04. Section Header You can set a floor limiting temperature between 20-45°C (28°C is the default setting). Note: Air Sensor only MUST NOT be used to control electric under-floor heating. Floor Sensor or Both should be used.
  • Page 26: Adjusting The Optional Settings

    Adjusting the Optional Settings Section Header • Use the Left / Right keys to select SETUP .............. • Press Tick to confirm selection .................. Feature Number Setting Value • Use the Up / Down keys to scroll through features .......... •...
  • Page 27 Optional Settings - Feature Table Section Header FEATURE DESCRIPTION SETTING Pairing Used to add zone to the neoHub Switching Differential 00 = 0.5°C 01 = 1.0°C (Default) 02 = 2.0°C 03 = 3.0°C Frost Protection Temperature 07° - 17°C (12°C = Default) Output Delay 00 - 15 Minutes (00 = Default) Up/Down Temperature Limit...
  • Page 28: Re-Calibrating The Thermostat

    Re-calibrating the Thermostat Section Header If you need to re-calibrate the thermostat, follow these steps. • Use the Left / Right keys to scroll to the Power Icon ......• Press and hold Tick to turn the display OFF ............•...
  • Page 29: Wiring Diagrams

    Wiring Diagram - neoStat to UH1 Section Header Connecting neoStat to the UH1 Remote 12VDC Air Sensor The UH1 allows connection of up to eight Floor 12 volt neo thermostats. Sensor When connecting network thermostats to the UH1 use CAT5-FTP or BELDEN 9538.
  • Page 30: Wiring Diagrams

    Wiring Diagram - PRC Voltfree Switching Section Header Voltfree Switching With the Heatmiser PRC 12VDC Recommendations Max Cable Size - 1.5MM Back Box Depth - 35MM RT2 RT1 A2 A1 Max Load - 3 Amps FLOOR PROBE REMOTE AIR PROBE...
  • Page 31: Factory Reset

    Factory Reset Section Header To reset the device to factory default settings, follow these steps: • Use the Left / Right keys to scroll to SETUP ............• Press and hold the Tick key for 10 seconds ............• All of the icons on the display will appear for 2 seconds, then the display will show option 1 or 2.
  • Page 32: Mode 2 - Time Clock

    Mode 2 - Time Clock Section Header Series Series Series...
  • Page 33: Lcd Display

    LCD Display Section Header Day Indicator - Displays the day of the week. Mesh Symbol – Displayed when connected to the neoHub. Key Lock Indicator – Displayed when the KeyLock is Locked. Set – Displayed when changes are being made to the program schedule or current set point.
  • Page 34: Setting The Switching Times

    Setting the Switching Times Section Header To program the switching times, follow these steps. • Use the Left / Right keys to scroll to EDIT and press Tick ......... • Use the Left / Right keys to select day/period of the week ......•...
  • Page 35: Timer Override

    Timer Override Section Header To override the timed output on, follow these steps. • Use the Up / Down keys to set the override duration e.g. 02:00 hours ..• Press Tick to confirm settings and return to main display ........Hold Left and the remaining time will now be displayed.
  • Page 36: Optional Features

    Optional Features Explained Section Header Feature 01 – Pairing To neoHub: This function is used to connect the time clock to the neoHub. Feature 02 - Weekday/Weekend (5/2), 7 Day Programming or 24 Hour Mode: The time clock offers three programming methods; Weekday/ Weekend (5/2) - Allows you to program 4 on/off switching times for the weekdays and 4 on/off switching times for the weekend.
  • Page 37: Notes

    Notes ........................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 38 Notes ........................................................................................................................................................................................................................................................................................................................................................................................................................................................Model: Manual REF Series...
  • Page 39 Notes ........................................................................................................................................................................................................................................................................................................................................................................................................................................................
  • Page 40 Want More Information? Call our support team on: +44 (0)1254 669090 Or view technical specifications directly on our website: www.heatmiser.com Twitter: @heatmiseruk Facebook: facebook.com/thermostats Rev.2.1...

Table of Contents

Save PDF