Table of Contents Product Image Locking/Unlocking the neoStat Table of Contents Frost Protection What is a Programmable Power ON/OFF Room Thermostat? Holiday Programming Installation Procedure 23-26 Optional Features Mode Select Re-calibrating the Thermostat Pairing the neoHub Error Codes Pairing the neoStat...
What is a Programmable Room Thermostat? Section Header A programmable room thermostat is both a programmer and a room thermostat. A programmer allows you to set “On” and “Off” periods to suit your own lifestyle. A room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached.
Page 5
Section Header The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature –...
Do not push hard on the LCD screen as this may cause irreparable damage. This neoStat is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation.
Mode Select Section Header This neoStat can either be used as a thermostat or a time clock. Thermostat mode is the default setting. To change between thermostat or time clock modes, follow these steps. • Use the Left / Right keys to scroll to SETUP ..............
• Select Add Zone, enter a zone title and press Add Zone again. • You now have two minutes to join the neoStat to the neoHub. • On the neoStat, use the Left / Right keys to select SETUP and press Tick ... • Feature 01 is displayed on screen.
• Press the Tick key to pair the neoStat to the neoHub ........Section Header • The MESH symbol appears flashing on the display. • When the neoStat successfully connects to the neoHub the MESH symbol will be permanently displayed.
LCD Display Section Header Day Indicator - Displays the day of the week. Mesh Symbol - Displayed when connected to the neoHub. Floor Limit Symbol - Displayed when the floor probe has reached the temperature limit set on feature 07. Frost Symbol - Displayed when frost protection mode is active.
Room Temperature Floor Temperature When the neoStat is set to use both the air & the floor sensor, the room temperature will be displayed by default. To view the current floor temperature, press and hold the Left and Right arrow keys for 5 seconds, the floor temperature will then be displayed ........
Setting the Clock Section Header To set the clock, follow these steps. • Use the Left / Right keys to scroll to CLOCK ............• Press Tick to confirm selection ................... • Use the Up / Down keys to set the hours (24 hour format) ......•...
Comfort Levels Explained Section Header The neoStat offers three program mode options; Weekday/Weekend programming, 7 Day programming and 24 Hour programming. There is also the option to use the thermostat as a Non-Programmable thermostat. When thermostats are connected to the mesh network, the program mode for the system is configured by using the neoApp.
Page 17
Section Header • Use the Up / Down keys to set the hours .............. • Press Tick to confirm ......................• Use the Up / Down keys to set the minutes ............• Press Tick to confirm ......................• Use the Up / Down keys to set the temperature ..........•...
Temperature Control Section Header The Up / Down keys allow you to adjust the set temperature ......When you press either key, you will see the word SET and the desired temperature value. Use the Up / Down keys to adjust the SET value ....Press Tick to confirm settings and return to the main display ........
Temperature Hold Section Header The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period. • Use the Left / Right keys to scroll to HOLD ............• Press Tick to confirm selection ..................•...
The frost icon will toggle ON/OFF each time Tick is pressed ..........In this mode, the neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature (see page 23).
The frost icon will toggle ON/OFF each time Tick is pressed ..........In this mode, the neoStat will display the frost icon and will only turn the heating ON should the room temperature drop below the set frost temperature (see page 23).
When the flame icon is absent, there is no requirement for heating to achieve the set temperature but the neoStat remains active. To turn the neoStat off completely, scroll to the Power Icon and hold the Tick key for approximately 4 seconds until the display goes blank ....
Holiday Section Header In thermostat mode, the holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 23). In time clock mode, the holiday function maintains the timed output as OFF. The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return.
Feature 06 – Sensor Selection: On this neoStat, you can select which sensor should be used. You can select between air temperature only, floor temperature, or both. When you enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to prevent the floor from overheating.
Page 25
Feature 07 – Floor Temp Limit: This function is available when mode 07 is set to 03 or 04. Section Header You can set a floor limiting temperature between 20-45°C (28°C is the default setting). Note: Air Sensor only MUST NOT be used to control electric under-floor heating. Floor Sensor or Both should be used.
Adjusting the Optional Settings Section Header • Use the Left / Right keys to select SETUP .............. • Press Tick to confirm selection .................. Feature Number Setting Value • Use the Up / Down keys to scroll through features .......... •...
Page 27
Optional Settings - Feature Table Section Header FEATURE DESCRIPTION SETTING Pairing Used to add zone to the neoHub Switching Differential 00 = 0.5°C 01 = 1.0°C (Default) 02 = 2.0°C 03 = 3.0°C Frost Protection Temperature 07° - 17°C (12°C = Default) Output Delay 00 - 15 Minutes (00 = Default) Up/Down Temperature Limit...
Re-calibrating the Thermostat Section Header If you need to re-calibrate the thermostat, follow these steps. • Use the Left / Right keys to scroll to the Power Icon ......• Press and hold Tick to turn the display OFF ............•...
Wiring Diagram - neoStat to UH1 Section Header Connecting neoStat to the UH1 Remote 12VDC Air Sensor The UH1 allows connection of up to eight Floor 12 volt neo thermostats. Sensor When connecting network thermostats to the UH1 use CAT5-FTP or BELDEN 9538.
Factory Reset Section Header To reset the device to factory default settings, follow these steps: • Use the Left / Right keys to scroll to SETUP ............• Press and hold the Tick key for 10 seconds ............• All of the icons on the display will appear for 2 seconds, then the display will show option 1 or 2.
LCD Display Section Header Day Indicator - Displays the day of the week. Mesh Symbol – Displayed when connected to the neoHub. Key Lock Indicator – Displayed when the KeyLock is Locked. Set – Displayed when changes are being made to the program schedule or current set point.
Setting the Switching Times Section Header To program the switching times, follow these steps. • Use the Left / Right keys to scroll to EDIT and press Tick ......... • Use the Left / Right keys to select day/period of the week ......•...
Timer Override Section Header To override the timed output on, follow these steps. • Use the Up / Down keys to set the override duration e.g. 02:00 hours ..• Press Tick to confirm settings and return to main display ........Hold Left and the remaining time will now be displayed.
Optional Features Explained Section Header Feature 01 – Pairing To neoHub: This function is used to connect the time clock to the neoHub. Feature 02 - Weekday/Weekend (5/2), 7 Day Programming or 24 Hour Mode: The time clock offers three programming methods; Weekday/ Weekend (5/2) - Allows you to program 4 on/off switching times for the weekdays and 4 on/off switching times for the weekend.
Page 40
Want More Information? Call our support team on: +44 (0)1254 669090 Or view technical specifications directly on our website: www.heatmiser.com Twitter: @heatmiseruk Facebook: facebook.com/thermostats Rev.2.1...
Need help?
Do you have a question about the neostat and is the answer not in the manual?