Saving and managing data
11.2 Managing data
Loading data from a file
NOTICE
Protection of the machine
For safety reasons, the machine and setting data should only be transferred when the enable
is locked.
Procedure:
1. Select the "Load data from a file" option.
2. In the data structure, select the saved file and confirm with "OK".
3. In the drop-down list, select an object, e.g. a different axis or a different drive object, to which
you want to transfer the data and confirm with "OK".
4. Observe the safety instructions and check the enable signals at the machine and the drive.
5. For drive data, the "Load" softkey is used to transfer the data to the target object.
11.2.3
How to compare data
Compare data
Select the data sources to compare the data. For instance, compare the actual data in the
control system with data saved in a file.
Procedure:
1. Select the "Compare data" option.
2. In the data structure, select the data that you want to compare.
3. Press the "Add to list" softkey to transfer the data to the list in the lower area of the display.
4. Press the "Delete from list" softkey to remove the data again.
5. If the list contains more than two data objects, you can activate the checkbox to compare two
or more data objects from the list.
6. Press the "Compare" softkey to start the comparison. The display of the comparison results
can take some time for extensive parameter lists.
7. Press the "Legend" softkey to display or hide the legend. The following display is the default:
– Different parameters are displayed.
– Parameters that do not exist in both data sources, are displayed.
– The same parameters are not displayed.
352
CNC Commissioning: NC, PLC, Drive
Commissioning Manual, 12/2019, A5E48312804B AA