Troubleshooting; Error Codes; Fault Codes - Toro 04065 Operator's Manual

Lithium battery charger, greensmaster eflex 2120 traction unit
Hide thumbs Also See for 04065:
Table of Contents

Advertisement

Troubleshooting

Error Codes

Problem
Code E-0-0-1, or E-0-4-7
Code E-0-0-4
Code E-0-0-7
Code E-0-1-2
Code E-0-2-3
Code E-0-2-4
Code E-0-2-5
Code E-0-3-7
Code E-0-2-9, E-0-3-0, E-0-3-2, E-0-4-6,
or E-0-6-0

Fault Codes

Problem
F-0-0-1, F-0-0-2, F-0-0-3, F-0-0-4,
F-0-0-5, F-0-0-6, or F-0-0-7
Possible Cause
1. Battery high voltage
1. BMS or battery fault detected
1. Battery amp hour limit exceeded
1. Reverse polarity error
1. High AC voltage error (>270VAC)
1. Charger failed to initialize
1. Low AC voltage oscillation error
1. Re-programming failed
1. Communication error with battery
Possible Cause
1. Internal charger fault
8
Corrective Action
1. Ensure that the battery voltage is
correct and the cable connections are
secure; ensure that the battery is in
good condition.
1. Refer to the machine Operator Manual.
1. Possible causes include poor battery
health, very deeply discharged battery,
poorly connected battery, and/or
high parasitic loads on battery while
charging. Possible solutions: Replace
battery pack. Check DC connections.
Disconnect parasitic loads. This error
will clear once the charger is reset by
cycling DC.
1. The battery is connected to the charger
incorrectly. Ensure that the battery
connections are secure.
1. Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
1. The charger has failed to turn on
properly. Disconnect the AC input and
battery connection for 30 seconds
before retrying.
1. The AC source is unstable. Could
be caused by undersized generator
or severely undersized input cables.
Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
1. Software upgrade failure or script
operation failure. Ensure that the new
software is correct.
1. Ensure that the connection of the
signal wires to the battery is secure.
Corrective Action
1. Remove the AC connection and
battery connection for a minimum of
30 seconds and retry. If it fails again,
please contact an authorized Toro
distributor.

Advertisement

Table of Contents
loading

This manual is also suitable for:

04090

Table of Contents