Line Cross Sections For Reinforced Braking Resistors Hlr01.1; Requirements For Line Routing - Bosch Rexroth IndraDrive Project Planning Manual

Additional components
Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

9-18
Braking Resistors HLR01.1
10000
W
[kWs]
1000
P_s [kW]
100
10
1
1
9.8
Line Cross Sections for Reinforced Braking Resistors
HLR01.1

Requirements for Line Routing

Braking resistors for HCS03 ... 0210
Peak power P_s and Energy absorption W
10
Duty cycle [s]
Fig. 9-23:
Selection aid for braking resistors for HCS03.1E-W0210
According to the standards "Electronic equipment for use in power
installations" (EN 50178, chapter 5.3.2.1) and "Adjustable speed electrical
power drive systems" (EN 61800-5-1, chapter 4.2.5.4.2), a stationary
connection of the equipment grounding conductor is required. The
following requirement has to be complied with: cross section of equipment
grounding conductor at least 10 mm
Note:
For the equipment grounding conductor run lines with a cross
section corresponding to that of the lines for mains connection
at the drive controller HCS and having at least 10 mm
• The cross sections are valid for one phase each with multi-wire
conductors and are specified according to the regulations of VDE0298.
2
• Up to 50 mm
, single strands in the cable duct.
Rexroth IndraDrive
Energy
HLR01.1N-36K0-N05R4
HLR01.1N-23K0-N05R5
HLR01.1N-17K0-N05R1
HLR01.1N-12K5-N05R5
HLR01.1N-06K5-N06R1
Power
HLR01.1N-36K0-N05R4
HLR01.1N-23K0-N05R5
HLR01.1N-17K0-N05R1
HLR01.1N-12K5-N05R5
HLR01.1N-06K5-N06R1
100
2
(mechanical stability).
DOK-INDRV*-ADDCOMP****-PR02-EN-P
1000
2
.