Installation Hlb01.1; Electrical Data Hlb01.1 - Bosch Rexroth IndraDrive Project Planning Manual

Additional components
Hide thumbs Also See for Rexroth IndraDrive:
Table of Contents

Advertisement

Rexroth IndraDrive
8.4

Installation HLB01.1

Electrical Data HLB01.1

Designation
mains input voltage
braking resistor switch-on
threshold
continuous power
peak power
maximum regenerated
power
derating if devices are
1)
connected in parallel
control voltage:
control voltage
power consumption
max. inrush current
power dissipation:
basic power dissipation
DOK-INDRV*-ADDCOMP****-PR02-EN-P
Symbol
Unit
U
V
ZK
U
V
Bl
P
kW
BD
P
kW
BS
W
kWs
MAX
U
V
ST
P
W
ST
I
A
EIN ST
P
W
VG
1)
The factor of derating results from the balancing behavior. The
balancing behavior is determined by tolerance afflicted voltage
measurements in the single devices. Derating applies as well for the
continuous power as for the maximum allowed regenerated power.
Fig. 8-5:
Electrical Data
DC Bus Resistor Unit HLB01.1C and HLB01.1D
Type
HLB01.1C
DC (254...750)
820
1
100
100
0,8
24 ± 20%
14
3 (for 50 ms)
28
8-5
HLB01.1D
DC (254...750)
820
2
100
500
0,8
24 ± 5%
14
3 (for 50 ms)
28

Hide quick links: