Huawei SUN2000 Series User Manual page 46

Hide thumbs Also See for SUN2000 Series:
Table of Contents

Advertisement

SUN2000-(3KTL-10KTL)-M0
User Manual
Before inserting the positive and negative connectors into the positive and negative DC input
terminals of the SUN2000, check that the DC SWITCH is OFF.
Use the Amphenol Helios H4 PV connectors supplied with the SUN2000. If the PV
connectors are lost or damaged, purchase the connectors of the same model. The device
damage caused by incompatible PV connectors is not covered under any warranty.
Cables with high rigidity, such as armored cables, are not recommended as DC input
power cables, because poor contact may be caused by the bending of the cables.
Before assembling DC connectors, label the cable polarities correctly to ensure correct
cable connections.
After crimping the positive and negative metal contacts, pull the DC input power cables
back to ensure that they are connected securely.
Insert the crimped metal contacts of the positive and negative power cables into the
appropriate positive and negative connectors. Then pull back the DC input power cables to
ensure that they are connected securely.
Crimp the metal stamping forming contacts using crimping tool H4TC0003 (Amphenol,
recommended), H4TC0002 (Amphenol), PV-CZM-22100 (Staubli), or PV-CZM-19100
(Staubli). When choosing PV-CZM-22100 or PV-CZM-19100, do not use the locator.
Otherwise metal contacts would be damaged.
Figure 5-13 Crimping tool (H4TC0003)
(1) Locator
Issue 04 (2019-10-18)
The DC voltage measurement range of the multimeter must be at least 1100 V.
If the voltage is a negative value, the DC input polarity is incorrect and needs correction.
If the voltage is greater than 1100 V, too many PV modules configured in the same string. Remove
some PV modules.
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connections
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents