Station 1
Solid Red Station Wire - Connect to the Red/White solenoid wire
Red with Black Stripe Station Wire - Connect to the Black solenoid wire
Station 2
Solid Green Station Wire - Connect to the Red/White solenoid wire
Green with Black Stripe Station Wire - Connect to the Black solenoid wire
White Power/Communication Wire
Black Power/Communication Wire
Station 3
Solid Orange Station Wire - Connect to the Red/White solenoid wire
Orange with Black Stripe Station Wire - Connect to the Black solenoid wire
Station 4
Solid Blue Station Wire - Connect to the Red/White solenoid wire
Blue with Black Stripe Station Wire - Connect to the Black solenoid wire
Each station can activate up to
two DC Latching Solenoids.
1-Station
Decoder
Module
Station Wires
The Remote Gateway output board can
accommodate up to 100 stations . The
decoder modules can be connected in any
configuration using the four output paths.
The maximum communication wire length between the decoder
module and the solenoid is 410' (125m).
Recommended Cable for Decoder-to-Solenoid is the Paige® P7351D,
14 AWG, Solid Copper, 2-Conductor, Direct Burial cable.
To easily identify stations for troubleshooting,
install wires with the same color code as the station wires.
DC Latching
Solenoid
Red
Black
Out to additional
decoder modules
When possible, install the decoder module
in a valve box for ease of service.
Output Board
Paths –
1
Valve Box
Recommended Cable for Controller-to-Decoder
is the Paige® P7350D, 14 AWG, Solid Copper,
Jacketed 2-Conductor, Direct Burial cable.
2
3
4
Maximum communication wire
length between the controller
and the farthest decoder is
15,000' (4,500 m).