Manual Watering

The Manual Watering functions are used for additional watering if the irrigation program is not sufficient.
They can also be used to troubleshoot each station for proper operation. Pressing the Manual Watering Key accesses the
Multi-Manual function.
M-Manual - Select M-Manual to activate a station or group of stations with a specified runtime.
Multi-Manual Station Activation Directions
Manual station activation example: Activate stations 1–12 with a runtime of 5 minutes each and limit watering to 3 stations
simultaneously.
The Multi-Manual function is limited to the maximum simultaneous station settings of the gateway. In cases where a
program is running and a multi-manual activated, the gateway will activate all stations specified in the multi-manual
in addition to the currently activated stations. Thus, the multi-manual will allow the gateway to exceed the maximum
simultaneous station settings.
1. Press the Manual Watering Key
2. The cursor should be located in the Manual field, use the Input Dial
3. Press the Down Arrow
value of the first station being irrigated. For this example, select station 01.
4. Press the Right Arrow
If irrigating only one station, this value should be the same as the first value. For this example, select station 12.
5. Press the Right Arrow
hours, minutes and seconds (HH:MM:SS). Use the Input Dial
appropriate runtime value. For this example, set the value to 00:05:00.
6. Press the Down Arrow
Fill this line only if irrigating multiple ranges of stations, otherwise, leave this line blank.
7. Press the Down Arrow
maximum simultaneous irrigating stations. For this example, set the value to 03.
8. Once finished, press the Start Key
display.
Pressing the Home Key will save the entered values.
The gateway containing the desired station to be started can be selected by highlighting 'x' in the "BDx" field.
When finished, the display should read:
Manual: M-Manual
Sta#: 01-12
Sta#: -----
Simult: 03
Press START to water
When reviewing the Multi-Manual program by pressing the Manual Watering button, the display will deduct the
stations that watered or currently watering to the list.
Modifying the Multi-manual will append the added stations to the currently running manual. Currently running
stations will not be affected. The Gateway will run the stations in sequential order disregarding the order it was entered.

% (Percent) Adjust

The Percent Adjust feature is not used at this time.
24
.
to advance the cursor to the Sta#: field. Use the Input Dial
to advance the cursor to the next value. This value will indicate the last station of the range.
to advance the cursor to the next entry field. This entry field will indicate the runtime in
to advance the cursor to the next entry field. Notice that a new Station: line was created.
to advance the cursor to the Simult: field. Use the Input Dial