Connecting The Station Wires (Includes Pump Relay) - Toro 24 User Manual

Intelli-sense professional controllers
Table of Contents

Advertisement

4.
Insert the ground wire into the copper ground lug and tighten
securely.
Connecting the Station Wires
Note: Using 18 AWG (or larger) irrigation valve connection cable or
wire is recommended for all field wire connections.
1.
To provide a valve common connection, interconnect one control
wire (generally white) to either lead of each valve solenoid.
2.
Connect a separate control wire to the remaining lead of each
valve solenoid. For reference, note the wire color used for each
valve connection, it's corresponding watering zone and the
intended station number.
3.
If a master valve or pump start relay is used, make this connection
in the same manner.
4.
Route the control wires into the controller cabinet through the
large opening provided or through conduit if installed.
5.
Cut wires back as necessary to provide an appropriate length for
connection. Strip 3/8"(10mm) insulation from each wire.
74
VC/
VC/
25 26 27 28 29 30 31 32 33 34 35 36
37 38 39 40 41 42 43 44 45 46 47 48
COM
COM
VC/
VC/
25 26 27 28 29 30 31 32 33 34 35 36
37 38 39 40 41 42 43 44 45 46 47 48
COM
COM
MV/
VC/
VC/
1
2
3
4
5
6
7
8
9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24
PUMP
COM
COM
MV/
1
2
3
4
5
6
7
8
9 10 11 12
VC/
VC/
13 14 15 16 17 18 19 20 21 22 23 24
PUMP
COM
COM
Valve Box
6 AWG Solid
Copper Wire
12" (30.5cm)
Ground Rod