Set Reference Et Value; Set Reference Month - Toro 24 User Manual

Intelli-sense professional controllers
Table of Contents

Advertisement

Set Reference [weekly] ET Value (applies to User With ET mode only)
The Reference ET is the weekly ET set in the User – With ET mode that
your runtimes correspond to. Runtimes will be adjusted up or down
automatically depending on whether the actual weekly ET is higher or lower
than the Reference ET. The default Reference ET is 1.00 (0.14 inches per day).
It is recommended that you set runtimes and the Reference ET value based
on the highest weekly ET demand period of the year.
Turn the Upper Line knob to view the following display:
1.
REF. ET PART 1 STA 01
1.00 (Weekly ET 1.00)
The whole number of the Reference ET value is selected by default.
2.
To adjust the value from 1 – 3, turn the Lower Line knob.
Note: TheReference ET value is adjustable from 0.50 – 3.99.
The whole number is only adjustable to 0 when the decimal
number value is .50 or higher.
Turn the Upper Line knob right to select the decimal number.
3.
Turn the Lower Line knob to adjust the decimal number value.
4.
Note: If the station uses the Days of Week by Month,
watering day mode, the Reference Month screen will be
displayed as shown below. To adjust this setting, continue at
step 5. If not applicable, the Program Complete screen will
be shown.
Turn the Upper Line knob to view the following display:
5.
REFERENCE MONTH
Jul (If Days by Month)
6.
Turn the Lower Line knob to select the preferred month.
36
STA 01

Advertisement

Table of Contents
loading

This manual is also suitable for:

12483612-station24-station36-station ... Show all