Installation

7.6 Without installation

If the unit does not have the window slider kit and wall exhaust, and the Adaptor B is like this ,as
shown in Fig G. You can open the window slightly and position as shown in Fig H.

7.7 Water drainage

• During dehumidifying mode, remove the upper drain plug from the back of the unit. Attach the drain
hose to the hole. Place the other end of the hose in the drainage way or other drain areas.
• If the unit you bought has the pump drain outlet, as shown below, please drain in this way :
Remove the pump drain plug from the back of the unit, attach the drain hose to the hole. Place the
other end of the hose in the drainage way or other drain areas.
Pump drain
outlet
34 / 88 EN
Fig. G
Drain outlet
Fig. H