6. Checks to the refrigeration equipment:
Where electrical components are being changed, they shall be
fit for the purpose and to the correct specification. At all times
the manufacturer's maintenance and service guidelines shall
be followed. If in doubt, consult the manufacturer's technical
department for assistance. The following checks shall be applied
to installations using flammable refrigerants:
• T he charge size is in accordance with the room size within which
the refrigerant containing parts are installed.
• T he ventilation machinery and outlets are operating adequately
and are not obstructed.
• I f an indirect refrigerating circuit is being used, the secondary
circuit shall be checked for the presence of refrigerant.
• R efrigeration pipe or components are installed in a position
where they are unlikely to be exposed to any substance which
may corrode refrigerant containing components, unless the
components are constructed of materials which are inherently
resistant to being corroded or are suitably protected against being
so corroded.
7. Checks to electrical devices:
Repair and maintenance to electrical components shall include
initial safety checks and component inspection procedures. If
a fault exists that could compromise safety, then no electrical
supply shall be connected to the circuit until it is satisfactorily
dealt with. If the fault cannot be corrected immediately but it
12 / 88 EN