Notice of installation

6.1 Unpacking inspection

• Open the box and check unit in area with good ventilation (open the door and window) and without
ignition source.
C
Note: Operators are required to wear anti-static devices.
• It is necessary to check by professional whether there is refrigerant leakage before opening the
box; stop installing the air conditioner if leakage is found.
• The fire prevention equipment and anti-static precautions shall be prepared well before checking.
Then check the refrigerant pipeline to see if there is any collision traces, and whether the outlook is
good.

6.2 Safety principles for installing air conditioner

• Fire prevention device shall be prepared before installation.
• Keep installing site ventilated.(open the door and window)
• Ignition source, smoking and calling is not allowed to exist in area where R290 refrigerant located.
• Anti-static precautions in necessary for installing air conditioner, e.g. wear pure cotton clothes and
gloves.
• Keep leak detector in working state during the installation.
• If R290 refrigerant leakage occurs during the installation, you shall immediately detect the
concentration in indoor environment until it reaches a safe level. If refrigerant leakage affects the
performance of the unit, please immediately stop the operation, and the unit must be vacuumed
firstly and be returned to the maintenance station for processing.
• Keep electric appliance, power switch, plug, socket, high temperature heat source and high static
away from the area underneath sidelines of unit.
• The unit shall be installed in an accessible location to installation and maintenance, without
obstacles that may block air inlets or outlets of units, and shall keep away from heat source,
inflammable or explosive conditions.

6.3 Requirements for installation position

• Avoid places of inflammable or explosive gas leakage or where there are strongly aggressive gases.
• Avoid places subject to strong artificial electric/magnetic fields.
• Avoid places subject to noise and resonance.
28 / 88 EN