Technologies and cycles
21.1
Activating turning/milling/drilling/grinding technologies
The cycles are automatically loaded when the controller boots (Power On).
The configuration is realized using cycle machine data and cycle setting data. In so doing, a
differentiation is made between the following data:
● General cycle machine data
● Channel-specific cycle machine data
● Axis-specific cycle machine data
● General cycle setting data
● Channel-specific cycle setting data
● Axis-specific cycle setting data
Requirement for memory configuration
To ensure that the cycles run correctly, the following standard setting must be checked:
MD28082 $MC_MM_SYSTEM_FRAME_MASK
Bit 5
= 1
MD52201 $MCS_TECHNOLOGY_EXTENSION
= 1
= 2
Note
Cylindrical and surface grinding are not supported as a technology extension by SINUMERIK
Operate.
SINUMERIK Operate (IM9)
Commissioning Manual, 12/2017, 6FC5397-1DP40-6BA1
System frame for cycles
Default setting
Additional settings for turning
Additional settings for turning,
e.g. turnign machine with milling technology
MD52200 $MCS_TECHNOLOGY = 1
MD52201 $MCS_TECHNOLOGY_EXTENSION = 2
System frames (SRAM)
Technology extension for combined machines
with several technologies
21