Chapter 2 Configuring and Upgrading the System
*3 Input the volume label as required. For more than one partition, "<Input value>_s<Partition number> is
set.
*4 Input "y" if there is no problem.
*5 If the confirmation message appears, input "y". This message appears as many as the number of the
created partitions at a maximum.
3. Execute "1 List RAID Arrays" of the ftdiskadm command to check that the hard disk has been correctly
duplicated.
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
4 Repair Mirroring Arrays (RAID1)
5 Delete Mirroring Arrays (RAID1)
6 Remove Disk Partitions (RAID1)
7 Make Striping Array
8 Delete Striping Array
c Configurations
q Quit
Command: 1
[List RAID Arrays]
Name Partition
===============================================================================
< Mirroring Array (RAID1)
md0
md1
md2
md123 /var/crash
md124 /boot/efi
md125 swap
md126 /boot
md127 /
<Descriptions>
Name
Partition
Status
Tips
The volume label can be changed with the commands such as e2label.
(RAID1)
(RAID1+0)
(RAID1+0)
Status
>
DUPLEX
DUPLEX
DUPLEX
DUPLEX
DUPLEX
DUPLEX
DUPLEX
DUPLEX
RAID device name
Mount point
RAID device status
Status
DUPLEX
SIMPLEX
RECOVERY(XX.X%)
RESYNC(XX.X%)
CHECK(XX.X%)
REPAIR(XX.X%)
RESYNC
Express5800/R320e-E4, R320e-M4 Maintenance Guide (Linux)
Member
(2)104002-part1
(10)114002-part1
(2)104002-part2
(10)114002-part2
(2)104002-part3
(10)114002-part3
(1)104001-part2
(9)114001-part2
(1)104001-part5
(9)114001-part5
(1)104001-part3
(9)114001-part3
(1)104001-part4
(9)114001-part4
(1)104001-part1
(9)114001-part1
Description
Duplicated normally.
Only one side of RAID is installed. The uninstalled member
is not displayed. In this case, repair is required.
The device out of the redundancy configuration is being
created again (resynchronization). If it is completed, the
status changes to "DUPLEX".
The redundancy configuration is being calculated again.
The data integrity is being checked.
The data integrity is being checked/repaired.
Recovery or synchronization processing is being waited for.
If "R" is added to the member, its recovery processing is
being waited for.
1. Hard Disk Drive Duplexing