Failure Code [Ca325] Inj #6 (L/B#6) Open/Short Error - Komatsu ecot3 PC300LC-8 Shop Manual

Hydraulic excavator
Table of Contents

Advertisement

40 Troubleshooting

Failure code [CA325] Inj #6 (L/B#6) Open/Short Error

Action code
Failure code
E11
Contents of
• Opening or short circuit was detected in drive circuit of No. 6 injector.
trouble
Action of con-
• Turns the centralized warning lamp and alarm buzzer ON.
troller
Problem that
appears on
• Combustion becomes irregular or engine hunts.
machine
Related infor-
• Method of reproducing failure code: Start engine.
mation
1 Defective engine controller
2 Defective No. 6 injector
Disconnection in wiring har-
ness
3
(Disconnection in wiring or
defective contact in connec-
tor)
Ground fault in wiring har-
ness
4
Possible causes
(Short circuit with GND cir-
and standard
cuit)
value in normal
state
Short circuit in wiring har-
5
ness
(with another wiring harness)
Defective wiring harness
6
connector
7 Defective engine controller
PC300, 350-8
Trouble
CA325
Cause
Injector #6 (L/B#6) open/short circuit error
(Engine controller system)
Standard value in normal state/Remarks on troubleshooting
If following failure codes are also displayed, trouble is in engine con-
troller: [CA323], [CA325], [CA332]
a
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
C11 (male)
Between (1) – (2)
Between (2) – chassis ground
a
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between CE01 (female) (57)
– C11 (female) (2)
Wiring harness between CE01 (female) (59)
– C11 (female) (1)
a
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between CE01 (female) (57)
– C11 (female) (2) and chassis ground
a
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Between CE01 (female) (57) – each of CE01
(female) pins (With all wiring harness con-
nectors disconnected)
Between CE01 (female) (59) – each of CE01
(female) pins (With all wiring harness con-
nectors disconnected)
Connecting parts between No. 6 injector – engine wiring harness –
engine controller may be defective. Check them directly.
• Looseness of connector, breakage of lock, or breakage of seal
• Corrosion, bend, breakage, push-in, or expansion of pin
• Moisture or dirt in connector or defective insulation
a
Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
CE01 (female)
Between (57) – (59)
Between (57) – chassis ground
SEN02629-03
1
Resistance
Max. 2 z
Min. 100 kz
Resis-
Max. 2 z
tance
Resis-
Max. 2 z
tance
Resis-
Max. 2 z
tance
Resis-
Min.
tance
100 kz
Resis-
Min.
tance
100 kz
Resistance
Max. 2 z
Min. 100 kz