WARNING
The frequency converter DC link capacitors remain
charged after power has been disconnected. To avoid
electrical shock hazard, disconnect the drive from the
mains before carrying out maintenance. Before doing
service on the drive wait at least the amount of time
indicated below
380- 480V
125-300hp
350-1200hp
525-690V
125-400hp
500-1350hp
These Operating Instructions can be used for all AF-650 GP
frequency converters with software version 2.1x.
The software version number can be seen from ID-43 Software
Version.

2.1.2 High Voltage

WARNING
The voltage of the frequency converter is dangerous
whenever the drive is connected to mains. Incorrect instal-
lation or operation of the motor or frequency converter
may cause damage to the equipment, serious personal
injury or death. The instructions in this manual must
consequently be observed, as well as applicable local and
national rules and safety regulations.
6
AF-650 GP High Power Operating Instructions
Equipment containing electrical
components may not be disposed of
together with domestic waste.
It must be separately collected with
electrical and electronic waste according
to local and currently valid legislation.
20 minutes
40 minutes
20 minutes
30 minutes
AF-650 GP
Operating Instructions
Software version: 2.1x
WARNING
Installation in high altitudes
380 - 480V: At altitudes above 3km, please contact GE
regarding PELV.
525 - 690V: At altitudes above 2km, please contact GE
regarding PELV.

2.1.3 Safety Instructions

Make sure the drive is properly connected to
earth.
Protect users against supply voltage.
Protect the motor against overloading according
to national and local regulations.
Motor overload protection is not included in the
default settings. To add this function, set
F-10 Electronic Overload to value Elec. OL trip or
Elec. OL warning. For the North American market:
Electronic Thermal Overload functions provide
class 20 motor overload protection, in accordance
with NEC.
The earth leakage current exceeds 3.5mA.
The [OFF] key is not a safety switch. It does not
disconnect the drive from mains.
2.1.4 General Warning
WARNING
Warning:
Touching the electrical parts may be fatal - even after the
equipment has been disconnected from mains.
Also make sure that other voltage inputs have been
disconnected, such as load-sharing (linkage of DC
intermediate circuit), as well as the motor connection for
kinetic back-up.
When using the drive: wait at least 40 minutes.
Shorter time is allowed only if indicated on the nameplate
for the specific unit.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents