10.1.4
Safety Information
Danger to life
It is not permitted to open the device or to modify the device.
The following must also be taken into account:
Failure to observe this requirement shall constitute a revocation of the CE approval, UL
For installation of the power supply, compliance with the DIN/VDE requirements or the
The field of application of the power supply is limited to "Information technology in
When the equipment is installed, it must be ensured that the mains socket outlet is
The housing can reach a temperature of +25 °C during operation without any adverse
NOTICE
The wide-range power supply unit must only be used for SIMATIC products in the
specifically described operating range and for the documented intended use.
If the wide-range power supply unit for SIMATIC RF systems (MLFB: 6GT2 898-0AA20) is
used for an end product other than the SIMATIC RF600 system, the following must be taken
into account:
● The electric strength test of the end product is to be based upon a maximum working
● The following secondary output circuits are SELV (low voltage; SELV = Safety Extra Low
● The following secondary output circuits are at non-hazardous energy levels: all
● The power supply terminals and/or connectors are suitable for field wiring if terminals are
MOBY D
System Manual, 01/2010, J31069-D0147-A6-7618
WARNING
certification for the US and Canada as well as the manufacturer's warranty.
country-specific regulations is essential.
electrical office equipment" within the scope of validity of the EN 60950/VDE 0805
standard.
freely accessible.
consequences. It must, however, be ensured that the power supply is covered in the
case of a housing temperature of more than +25°C to protect persons from contact with
the hot housing. Adequate ventilation of the power supply must be maintained under
these conditions.
voltage of: Transition from primary to SELV: 353 V DC, 620 Vpk
Voltage): all
provided.
10.1 Wide-range power supply unit for SIMATIC RF systems
Accessories
269