Technical Data - Siemens SIMATIC MOBY D System Manual

Rfid systems
Table of Contents

Advertisement

Write/read devices with RS422 interface
7.4 SLG D12S
7.4.3

Technical data

Table 7- 10
Inductive interface to the MDS
Transmission frequency
Transponders supported
Serial interface to the user
Transmission protocol
Data transmission rate
Data backup
Transmit power
Write/read distances SLG - MDS
Software functions
Programming
Transmission protocol
Multitag
Power supply
Current consumption
Cable length SLG – SIMATIC S7
Digital inputs/outputs
Enclosure dimensions (L x W x H) in
mm
Connector
Mounting
Ambient temperature
MTBF
Degree of protection according to EN
60529
186
Technical data for SLG D12S
Operation
Permissible range
Operation
Inrush current, momentary
With RS 422
Color
Material
RS 422 interface
Power supply
Operation
Transport and storage
13.56 MHz
Transponders according to ISO 15693 and I-Code1
RS 422
Asynchronous 8 bit
19.2 Kbaud
CRC 16
1 W (reset parameter 04 hex)
160 mm typically (see field data)
Read, write and initialize MDS
Concatenated commands are not permitted.
The Repeat command is not implemented.
The largest possible useful data length in a command is
233 bytes.
FC 45
3964R
no
150 mA
600 mA
300 m
None
160 x 80 x 40 (without connector)
Anthracite
Plastic PA 12
9-pin Sub-D connector (male)
4-pin M12 connector (male)
2 x M5 screws
-25 °C to +55 °C
-25 °C to +70 °C
2.0 x 10
hours
5
IP65 (UL: for indoor use only)
System Manual, 01/2010, J31069-D0147-A6-7618