Table 6- 5
Inductive interface to the MDS
Transmission frequency
Transponders supported
Serial interface to the user
Transmission protocol
Data transmission rate
Data backup
Transmit power
Write/read distances SLG - MDS
Software functions
Programming
Multitag
Anti-collision speed
Power supply
Current consumption
Cable lengths
Digital inputs/outputs
Enclosure dimensions (L x W x H) in mm
Color
Material
Connector
Mounting
Ambient temperature
MTBF
Degree of protection according to EN 60529
Shock resistant according to EN 60721-3-7 Class 7M2
Total shock response spectrum Type II
154
Technical data for SLG D10 basic unit
Operation
Inrush current, momentary
With RS 232
Antenna
V24 interface
Power supply
Operation
Transport and storage
13.56 MHz
Transponders according to ISO 15693 and
I-Code1
RS 232 (RS 422 on request)
Asynchronous 8 bit
9600 baud to 115.2 Kbaud
(adjustable)
CRC 16
up to 10 W
650 mm typically (see field data)
Read, write, initialize MDS, access rights,
multitag
Windows 9x, 2000, NT, XP with 32 bit DLL
available
Yes
approx. 20 labels/s simultaneously
identifiable
up to 1.4 A
2.8 A/50 ms
30 m (depending on baud rate)
None
320 x 145 x 100 (without connector)
Anthracite
Aluminum
TNC connector
9-pin Sub-D connector (male)
4-pin M12 connector (male)
4 x M6 screws
-20 °C to +55 °C
-25 °C to +70 °C
7.5 x 10
hours
4
IP65 (UL: for indoor use only)
30 g
System Manual, 01/2010, J31069-D0147-A6-7618