40 Troubleshooting
E-24 While starting switch is in OFF position, service meter is not
Trouble
• When starting switch is turned OFF, service meter is not displayed.
• While starting switch is at OFF position, if following switches are operated, service meter is dis-
Related
played at top center of screen.
information
Operation of switches: [4] + [1] (Press simultaneously)
Possible causes
Defective backup power sup-
and standard
1
ply system
value in normal
state
2 Defective machine monitor
E-25 Machine monitor cannot be set in service mode
Trouble

• Machine monitor cannot be set in service mode.

Related
• If following switches are operated, machine monitor is set in service mode.
Operation of switches: [4] + [1] o [2] o [3] (While pressing [4], press other switches in order)
information
Possible causes
and standard
value in normal
1 Defective machine monitor
state
PC130-8
Cause
Standard value in normal state/Remarks on troubleshooting
When starting switch is turned ON, if machine monitor displays
nothing, backup power supply system may be defective. In this
case, carry out troubleshooting for "E-1 When starting switch
turned ON, machine monitor displays nothing".
If cause 1 is not detected, machine monitor may be defective.
(Since trouble is in system, troubleshooting cannot be carried out.)
Cause
Standard value in normal state/Remarks on troubleshooting
Machine monitor may be defective. (Since trouble is in system,
troubleshooting cannot be carried out.)