SEN04120-03

Failure code [DA29KQ] Model selection abnormality

User code
Failure code
DA29KQ
Contents of
• Model code signal for model which is not registered in controller is input.
trouble
Action of
• Changes input model code to code of default model (PC120) and continues control.
controller
• Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF.
Problem that
appears on
• Since control is carried out on assumption that model is PC120, no particular problem occur.
machine
• Model code of pump controller can be checked with monitoring function.
(Code: 00200 Controller model code)
Related
• Condition of model selection signal can be checked with monitoring function.
information
(Code: 02209 Switch input 6)
• Method of reproducing failure code: Turn starting switch ON.
Defective model selection
1
connector (Internal discon-
nection or short circuit)
Disconnection in wiring har-
ness (Disconnection in wiring
2
or defective contact in con-
nector)
Possible causes
and standard
value in normal
state
Ground fault in wiring har-
3
ness (Short circuit with GND
circuit)
4 Defective pump controller
46
Model selection abnormality
Trouble
(Pump controller system)
Cause
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Between (3), (4), (7) – (8)
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between CP01 (female) (21)
– S30 (male) (2)
Wiring harness between CP01 (female) (40)
– S30 (male) (1)
Wiring harness between S30 (male) (8) –
J05 – chassis ground (T07)
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Wiring harness between CP01 (female) (77)
– S30 (male) (3) and chassis ground
Wiring harness between CP01 (female) (58)
– S30 (male) (4)
Wiring harness between CP01 (female) (39)
– S30 (male) (7)
a Prepare with starting switch OFF, then carry out troubleshoot-
ing without turning starting switch ON.
Between (39), (58), (77) – chas-
Between (21), (40) – chassis
S30 (female)
Between (1), (2) – (8)
CP01 (female)
sis ground
ground
40 Troubleshooting
1
Resistance
Min. 1 Mz
Max. 1 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Min. 1 Mz
tance
Resis-
Min. 1 Mz
tance
Resis-
Min. 1 Mz
tance
Resistance
Min. 1 Mz
Max. 1 z
PC130-8

Advertisement

Table of Contents
loading

Table of Contents