2 Preparation before use

2.2.3. Parameter setting example 1 (When the Support Software is used)

The setting example to use the Support Software is shown below.
Set the parameters for the robot controller, and the network for the personal computer OS being used.
IP address of robot controller
IP address of personal computer
Port No. of robot controller
Set the robot controller parameters as shown below.
If the default settings are to be used, the parameters do not need to be changed.
Parameter
NETIP
NETPORT
Next, set the personal computer IP address to 192.168.0.10. Set this value on the Network Properties screen.
The personal computer IP address is set with the Windows TCP/IP Property Network setting (property in network
computer). Because the set-up screen differs with versions of Windows, refer to the manuals enclosed with Windows, etc.,
for details on setting this address.
Refer to the instruction manuals enclosed with the personal computer support software for details on setting and using the
personal computer support software.
2-8
Conditions for example 1
192.168.0.20
192.168.0.10
10001
Parameter setting for example 1
Before/after
change
Before
192.168.0.20
After
192.168.0.20 (unchanged)
Before
10001
After
10001 (unchanged)