GE 489 Instruction Manual page 175

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (Sheet 21 of 29)
ADDR NAME
2565
RTD #6 TRIP
2566
RTD #6 TRIP VOTING
2567
ASSIGN TRIP RELAYS (1-4)
2568
RTD #6 TRIP TEMPERATURE
2569
RTD #6 NAME
RTD TEMPERATURE / RTD #7
25A0
RTD #7 APPLICATION
25A1
RTD #7 ALARM
25A2
ASSIGN ALARM RELAYS (2-5)
25A3
RTD #7 ALARM TEMPERATURE
25A4
RTD #7 ALARM EVENTS
25A5
RTD #7 TRIP
25A6
RTD #7 TRIP VOTING
25A7
ASSIGN TRIP RELAYS (1-4)
25A8
RTD #7 TRIP TEMPERATURE
25A9
RTD #7 NAME
RTD TEMPERATURE / RTD #8
25E0
RTD #8 APPLICATION
25E1
RTD #8 ALARM
25E2
ASSIGN ALARM RELAYS (2-5)
25E3
RTD #8 ALARM TEMPERATURE
25E4
RTD #8 ALARM EVENTS
25E5
RTD #8 TRIP
25E6
RTD #8 TRIP VOTING
25E7
ASSIGN TRIP RELAYS (1-4)
25E8
RTD #8 TRIP TEMPERATURE
25E9
RTD #8 NAME
RTD TEMPERATURE / RTD #9
2620
RTD #9 APPLICATION
2621
RTD #9 ALARM
2622
ASSIGN ALARM RELAYS (2-5)
2623
RTD #9 ALARM TEMPERATURE
2624
RTD #9 ALARM EVENTS
2625
RTD #9 TRIP
2626
RTD #9 TRIP VOTING
2627
ASSIGN TRIP RELAYS (1-4)
2628
RTD #9 TRIP TEMPERATURE
2629
RTD #9 NAME
RTD TEMPERATURE / RTD #10
2660
RTD #10 APPLICATION
2661
RTD #10 ALARM
2662
ASSIGN ALARM RELAYS (2-5)
2663
RTD #10 ALARM TEMPERATURE
2664
RTD #10 ALARM EVENTS
2665
RTD #10 TRIP
2666
RTD #10 TRIP VOTING
2667
ASSIGN TRIP RELAYS (1-4)
2668
RTD #10 TRIP TEMPERATURE
2669
RTD #10 NAME
RTD TEMPERATURE / RTD #11
26A0
RTD #11 APPLICATION
26A1
RTD #11 ALARM
26A2
ASSIGN ALARM RELAYS (2-5)
1, 2, 3
See Table footnotes on page 6–39
GE Power Management
RANGE
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
1 to 250
0 to 1
0 to 2
1 to 12
0 to 3
1 to 250
0 to 8
0 to 4
0 to 2
1 to 4
489 Generator Management Relay
6.3 MEMORY MAP
STEP
UNITS
FORMAT
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
1
°C
F1
1
F105
1
F115
1
F122
1
F50
1
°C
F1
1
F22
1
F121
1
F115
1
F50
DEFAULT
0
6
1
155
_
2
0
16
80
0
0
7
1
90
_
2
0
16
80
0
0
8
1
90
_
6
2
0
16
80
0
0
9
1
90
_
2
0
16
80
0
0
10
1
90
_
4
0
16
6-31