GE 489 Instruction Manual page 169

Generator management relay
Hide thumbs Also See for 489:
Table of Contents

Advertisement

6 COMMUNICATIONS
Table 6–1: 489 MEMORY MAP (Sheet 15 of 29)
ADDR NAME
FLEXCURVE TRIP TIME AT 1.90 × PU
1733
FLEXCURVE TRIP TIME AT 2.00 × PU
1734
FLEXCURVE TRIP TIME AT 2.10 × PU
1735
FLEXCURVE TRIP TIME AT 2.20 × PU
1736
FLEXCURVE TRIP TIME AT 2.30 × PU
1737
FLEXCURVE TRIP TIME AT 2.40 × PU
1738
FLEXCURVE TRIP TIME AT 2.50 × PU
1739
FLEXCURVE TRIP TIME AT 2.60 × PU
173A
FLEXCURVE TRIP TIME AT 2.70 × PU
173B
FLEXCURVE TRIP TIME AT 2.80 × PU
173C
FLEXCURVE TRIP TIME AT 2.90 × PU
173D
FLEXCURVE TRIP TIME AT 3.00 × PU
173E
FLEXCURVE TRIP TIME AT 3.10 × PU
173F
FLEXCURVE TRIP TIME AT 3.20 × PU
1740
FLEXCURVE TRIP TIME AT 3.30 × PU
1741
FLEXCURVE TRIP TIME AT 3.40 × PU
1742
FLEXCURVE TRIP TIME AT 3.50 × PU
1743
FLEXCURVE TRIP TIME AT 3.60 × PU
1744
FLEXCURVE TRIP TIME AT 3.70 × PU
1745
FLEXCURVE TRIP TIME AT 3.80 × PU
1746
FLEXCURVE TRIP TIME AT 3.90 × PU
1747
FLEXCURVE TRIP TIME AT 4.00 × PU
1748
FLEXCURVE TRIP TIME AT 4.10 × PU
1749
FLEXCURVE TRIP TIME AT 4.20 × PU
174A
FLEXCURVE TRIP TIME AT 4.30 × PU
174B
FLEXCURVE TRIP TIME AT 4.40 × PU
174C
FLEXCURVE TRIP TIME AT 4.50 × PU
174D
FLEXCURVE TRIP TIME AT 4.60 × PU
174E
FLEXCURVE TRIP TIME AT 4.70 × PU
174F
FLEXCURVE TRIP TIME AT 4.80 × PU
1750
FLEXCURVE TRIP TIME AT 4.90 × PU
1751
FLEXCURVE TRIP TIME AT 5.00 × PU
1752
FLEXCURVE TRIP TIME AT 5.10 × PU
1753
FLEXCURVE TRIP TIME AT 5.20 × PU
1754
FLEXCURVE TRIP TIME AT 5.30 × PU
1755
FLEXCURVE TRIP TIME AT 5.40 × PU
1756
FLEXCURVE TRIP TIME AT 5.50 × PU
1757
FLEXCURVE TRIP TIME AT 5.60 × PU
1758
FLEXCURVE TRIP TIME AT 5.70 × PU
1759
FLEXCURVE TRIP TIME AT 5.80 × PU
175A
FLEXCURVE TRIP TIME AT 5.90 × PU
175B
FLEXCURVE TRIP TIME AT 6.00 × PU
175C
FLEXCURVE TRIP TIME AT 6.50 × PU
175D
FLEXCURVE TRIP TIME AT 7.00 × PU
175E
FLEXCURVE TRIP TIME AT 7.50 × PU
175F
FLEXCURVE TRIP TIME AT 8.00 × PU
1760
FLEXCURVE TRIP TIME AT 8.50 × PU
1761
FLEXCURVE TRIP TIME AT 9.00 × PU
1762
FLEXCURVE TRIP TIME AT 9.50 × PU
1763
FLEXCURVE TRIP TIME AT 10.0 × PU
1764
FLEXCURVE TRIP TIME AT 10.5 × PU
1765
FLEXCURVE TRIP TIME AT 11.0 × PU
1766
FLEXCURVE TRIP TIME AT 11.5 × PU
1767
1, 2, 3
See Table footnotes on page 6–39
GE Power Management
RANGE
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
0 to 65535
489 Generator Management Relay
6.3 MEMORY MAP
STEP
UNITS
FORMAT
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
1
ms
F1
DEFAULT
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
6
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
65535
6-25