88

Maintenance intervals

This table lists the routine maintenance intervals recommended by ABB.
Capacitor reforming
Heatsink temperature check
and cleaning
Cabinet air filter check;
replacement if necessary
Frame R4i and R5i inverter
modules: Change of
additional cooling fan
Frame R8i inverter modules:
Check and cleaning of power
connections
Cooling fan change
Frame R4i and larger
inverter modules: capacitor
renewal

Checking and replacing the air filters

Before replacing the air filters of the cabinet, read and repeat the steps in the safety
instructions above.

Heatsinks

Heatsink fins pick up dust from the cooling air. Inverter modules run into
overtemperature warnings and faults if the heatsink is not clean. In a "normal"
environment (not dusty, not clean) the heatsink should be checked annually, in a
dusty environment more often.
Clean the heatsink as follows (when necessary):
1. Remove the cooling fan as described in
2. Blow clean, dry compressed air from bottom to top and simultaneously use a
vacuum cleaner at the air outlet to trap the dust. Note: Prevent the dust from
entering adjoining equipment.
3. Refit the cooling fan.
Maintenance
Maintenance
Interval
Every year when stored
Depending on the dustiness of
the environment, every 6 to 12
months
Every year
Every 3 years
Every 4 years
Every 5 years
Every 10 years
Cooling fans
Instructions
See
Capacitor
reforming.
See Heatsinks.
See
Checking and replacing
the air
filters.
See
Cooling fans.
See
Power connections
See
Cooling
fans.
See Capacitors.
elsewhere in this chapter.
(R8i).