4.3 Judgment Output Setting
4.3.1 Judgment Hysteresis
Determine the hysteresis of the upper and lower limit values.
Enter the value corresponding to the display.
The hysteresis is defined inside the upper or lower limit value (in the GO
area).
Enter the setting corresponding to the displayed value.
Enter the value so that the following equation stands true:
Upper limit value (H-thr) - hysteresis width (o-hys) > Lower limit value
(L-thr) + hysteresis width (o-hys)
POINT
4.3.2 Output Style Selection
The output style of the open collector output (HI, GO and LO) issued upon
deviation from the tolerance judgment value can be selected.
Function No.
N.O. normally open
N.C. normally closed
Reference
For the judgment hysteresis and output style selection method, refer to
page 75.
Name
The tolerance judgment output is issued from a N.O.
N.O. output
contact (contact A).
The tolerance judgment output is issued from a N.C.
N.C. output
contact (contact B).
Description of action
73